Home » Electronic Measuring Instruments » Optical, Light & Color Measurement » Colorimeter » TechnoOptis UA-20C Luminance & Chromaticity Uniformity Analyzer

TechnoOptis UA-20C Luminance & Chromaticity Uniformity Analyzer

TechnoOptis UA-20C 2D Luminance and Chromaticity Uniformity Analyzer

High-resolution two-dimensional luminance and chromaticity mapping for next-generation displays, automotive lighting and production-line optical inspection.

The TechnoOptis UA-20C is a high-resolution imaging colorimeter that evaluates spatial brightness and color uniformity over a display, light source or optical material. Its 24.5-megapixel CMOS detector samples a 5328 × 4608 image, supporting fine-area Mura investigation and detailed optical R&D.

The standard, wide and telephoto versions cover 0.01–50,000 cd/m², while the macro UA-20CM is separately specified at 0.1–240,000 cd/m². Optional neutral-density filters can extend the supported high-brightness range to 500 million cd/m² on standard/wide/telephoto versions or 240 million cd/m² on the macro configuration.

Four optical configurations support distinct tasks: wide-angle viewing of large panels, standard production inspections, telephoto viewing from a distance, and close-up macro evaluation. Lens type must be selected during system design because measurement area, target pixel size and range depend on the optics.

Gigabit Ethernet data transfer, an external-control SDK and CI-100 measurement/analysis software support integration into production inspection and laboratory workflows. The fastest published measurement time is approximately three seconds and is condition-dependent.

If only luminance uniformity is required, compare the UA-20Y, which uses a dedicated Y filter and is not a chromaticity-measuring equivalent. The smaller UA-10A is another alternative where 2.3-megapixel spatial resolution is sufficient.

24.5 MP 5328 × 4608 CMOS measurement points
0.01–50,000 cd/m² Standard / wide / telephoto variants
4 lens versions Standard, wide, telephoto and macro
Approx. 3 s Fastest published measurement, conditional

24.5-Megapixel CMOS Array

The 5328 × 4608 imaging detector captures detailed two-dimensional luminance and chromaticity distributions.

Four Lens Configurations

Select standard, wide-angle, telephoto or macro optics for the required measurement geometry.

Wide Standard Luminance Range

The S/W/T versions cover 0.01–50,000 cd/m²; the macro version uses a separate specified range.

ND-Filter High-Brightness Expansion

Optional neutral-density filters extend supported measurement ranges for high-brightness micro LED and LED devices.

Automation-Ready Interfaces

GigE communication and an external-control SDK support automated inspection sequences and result transfer.

CI-100 Image Analysis

Measurement software provides different result views, spatial uniformity evaluation and optical analysis tools.

Micro LED and Mini LED Displays

Map fine spatial luminance and chromaticity variation over high-density emitter arrays.

OLED and LCD Uniformity QC

Analyze display Mura, edge variation and panel color differences across the field of view.

Automotive Instrument and Cabin Displays

Evaluate uneven brightness or color on dashboard panels, HMI displays and interior illumination.

AR/VR Display Modules

Study localized optical uniformity across small panels and near-eye display elements.

LED Lighting and Backlight Systems

Inspect large-area light distribution and chromaticity uniformity of lighting assemblies.

Automated End-of-Line Inspection

Integrate high-resolution optical checks into manufacturing data-collection and quality-screening workflows.

UA-20C Specifications

Model familyUA-20C
Model variantsUA-20CS / UA-20CW / UA-20CT / UA-20CM
Photo detector24.5-megapixel CMOS sensor
Measurement point array5328 × 4608
S/W/T luminance range0.01–50,000 cd/m²
Macro luminance range0.1–240,000 cd/m²
S/W/T optional ND-filter range5–500,000,000 cd/m² with compatible ND filter
Macro optional ND-filter range10–240,000,000 cd/m² with compatible ND filter
S/W/T luminance linearity±2% at or above 0.1 cd/m²; ±3% from 0.01 to 0.1 cd/m²
Macro luminance linearity±2% under reference conditions
S/W/T chromaticity accuracy±0.003 at or above 0.1 cd/m²; ±0.007 from 0.01 to 0.1 cd/m²
Macro chromaticity accuracy±0.003 under reference conditions
In-plane luminance uniformity±2% under manufacturer conditions
In-plane chromaticity uniformity±0.003 under manufacturer conditions
Luminance repeat characteristic0.3% (2σ) at or above 0.1 cd/m²; 0.5% below 0.1 cd/m²
Chromaticity repeat characteristic0.002 / 0.005 by luminance range (max–min)
Fastest published measurementApprox. 3 seconds; depends on conditions
Luminance stability±1%
Luminance repeatability±2%
CommunicationGigabit Ethernet (GigE)
IntegrationExternal-control SDK, CI-100 analysis software
PC operating systemsWindows 10 Pro / Windows 11 Pro (64-bit)
PC resourcesIntel Core i7-11700 or higher, 16 GB RAM or higher, 500 GB disk or higher
Full-size result dataApproximately 3 GB per full-size result in manufacturer documentation

Model and Lens Configuration

UA-20CS | Standardf = 35 mm; 122.8 × 69.3 × 59.5 mm; approx. 470 g
UA-20CW | Widef = 12 mm; 131.2 × 69.3 × 61.0 mm; approx. 510 g
UA-20CT | Telephotof = 50 mm; 131.3 × 69.3 × 61.0 mm; approx. 490 g
UA-20CM | MacroDistinct 0.1–240,000 cd/m² range; 154.7 × 69.3 × 59.5 mm; approx. 540 g
At 1,000 mm distanceUA-20CS: 375.4 × 324.7 mm; UA-20CW: 1094.9 × 946.9 mm; UA-20CT: 268.1 × 231.9 mm
Macro field at 5.5 mm6.5 × 5.6 mm (2.0× optical magnification, manufacturer table)

Manufacturer accuracy references standard illuminant A and center-of-CMOS measurements. Luminance and chromaticity accuracy vary with brightness and lens configuration.

Do not apply macro version ratings or optional ND-filter values to standard optics without checking the actual ordered model.