Home » Electronic Measuring Instruments » Optical, Light & Color Measurement » Spectroradiometer » TechnoOptis SR-5100 2D Spectroradiometer

TechnoOptis SR-5100 2D Spectroradiometer

SR-5100 5-Megapixel 2D Spectroradiometer

The TechnoOptis SR-5100 captures spatially resolved spectral radiance, luminance, and chromaticity using a 5-megapixel CMOS imaging sensor for advanced display, lighting, and material analysis.

Its spectral mode offers 2448 × 2048 effective pixels, 380–780 nm coverage, and 1 nm wavelength resolution. Under the manufacturer’s specified reference conditions, the spectral-mode luminance measurement range extends from 0.5 to 17,000,000,000 cd/m². This maximum is not the applicable range for all lenses or measurement modes.

The SR-5100 family supports high-resolution analysis of micro LED and OLED arrays, automotive displays, illuminated parts, optical coatings, and reflected or transmitted light. Spectral and XYZ-filter operating methods offer different sensitivity and measurement-range characteristics, so the intended model, lens, and mode should be confirmed when selecting a system.

2448 × 2048 5 MP spectral imaging
380–780 nm Spectral wavelength range
1 nm Wavelength resolution
Up to 17B cd/m² Spectral-mode upper limit*

5-megapixel spatial analysis

A 2448 × 2048 CMOS image enables high-resolution mapping of spectral information across a field.

Broad spectral-mode luminance range

Spectral-mode measurements reach up to 17 billion cd/m² under specified manufacturer conditions.

1 nm spectral sampling

Wavelength resolution of 1 nm across 380–780 nm supports detailed visible-light analysis.

Spectral and XYZ measurement paths

Spectral and XYZ-filter acquisition offer different performance tradeoffs for measurement workflows.

Precision calibration

Traceable-source calibration supports quantitative brightness and chromaticity evaluation.

Selectable lens configurations

Wide, telephoto, and macro optical options support different target sizes and working distances.

Micro LED and OLED Inspection

Map emission intensity and chromaticity across densely spaced pixels and emitters.

Display Mura Evaluation

Characterize spatial nonuniformity in brightness, spectral output, and chromaticity.

Automotive Display Testing

Assess optical performance across instrument displays, controls, and illuminated vehicle components.

LED Array Characterization

Analyze spatial distributions of light output from LED and OLED lighting assemblies.

Coatings and Material Analysis

Evaluate spectral reflectance, transmission-related response, and color variation in selected materials.

Optical and Biomedical Research

Investigate spectral characteristics of small regions; specialized microscope-based analysis requires the appropriate configuration.

Key specifications

Parameter Value
Detector 5.0 MP CMOS imaging sensor
Spectral-mode effective pixels 2448 × 2048
Spectral-mode wavelength range 380–780 nm
Spectral-mode wavelength resolution 1 nm
Spectral accuracy ±0.5 nm (Hg emission line; high-precision mode)
Spectral bandwidth 7 nm FWHM (high-precision mode)
Spectral-mode luminance range 0.5–17,000,000,000 cd/m² (standard illuminant A; specified configuration)
XYZ-filter-mode luminance range 0.005–100,000 cd/m² (standard illuminant A; mode-specific)
Spectral-mode luminance linearity ±2% (center pixel and reference conditions)
Spectral-mode in-plane uniformity Luminance ±2%; chromaticity ±0.003 (reference field and conditions)
Standard / wide lens f=32 mm standard; f=24 mm with wide attachment
Telephoto / macro f=140 mm telephoto; macro lens (model-dependent)
Interfaces USB 3.0; external trigger
Power / consumption 100–240 V AC adapter; approximately 20 W
Operating environment 0–35°C; ≤80% RH, non-condensing
Dimensions, wide / telephoto / macro 162 × 247 × 402.4 / 412.5 / 330.5 mm (W×H×D)
Weight, wide / telephoto / macro Approximately 6.3 / 8.2 / 5.8 kg

Spectral vs XYZ-filter mode (manufacturer values)

Parameter Spectral mode XYZ-filter mode
Measurement method Dispersed spectral imaging XYZ tristimulus filter imaging
Luminance range (cd/m²) 0.5–17,000,000,000 0.005–100,000
Reference imaging sensor 5 MP CMOS 5 MP CMOS
Spectral wavelength information 380–780 nm, 1 nm resolution Tristimulus filter outputs; not full 1 nm spectra
Important limitation High-end limit is spectral-mode-specific Low-end 0.005 cd/m² is filter-mode-specific

* The 17 billion cd/m² upper range applies to the manufacturer’s specified SR-5100 spectral-mode conditions. The XYZ-filter-mode reference luminance range is different and must not be combined with the spectral range. Lens choices, reference illuminant, calibration conditions, pixel position and instrument variant affect detailed accuracy. Verify exact configuration for procurement.