TechnoOptis SR-UL2 Spectroradiometer

SR-UL2 Ultra-Low-Luminance Spectroradiometer

The discontinued SR-UL2 is a high-sensitivity spot spectroradiometer for extremely low luminance and chromaticity evaluation in high-contrast displays.

At a 2° measurement angle, the SR-UL2 starts at 0.0005 cd/m² and measures up to 3,000 cd/m². The full angle-dependent operating envelope reaches 300,000 cd/m² at the 0.1° setting. It measures spectral radiance in the 380–780 nm visible range at 1 nm wavelength resolution.

The manufacturer specifies four motor-selectable observation angles, a cooled linear CCD, high-speed measurement mode, USB 2.0/RS-232C communication, and included CS-900A software. Approximately 17-second measurement at 0.005 cd/m² is a manufacturer-stated example, not the speed for all measurement conditions.

The product is discontinued, and SR-5A is the manufacturer-listed successor. Legacy documentation can support equipment maintenance and specification-based upgrade decisions.

0.0005 cd/m² Minimum at 2°
380–780 nm Visible spectral coverage
1 nm Wavelength resolution
Discontinued Manufacturer successor: SR-5A

Ultra-low light sensing

At 2°, the specified range begins at 0.0005 cd/m² for high-contrast display research.

Angle-specific measurement ranges

The maximum 300,000 cd/m² is specified at 0.1°, with different thresholds at other angles.

Four motorized observation angles

Select 2°, 1°, 0.2°, or 0.1° to match target geometry.

High-speed measurement mode

Approx. 17 seconds at 0.005 cd/m² is a cited example; actual time depends on target and mode.

Spectral/color analysis

Supports luminance, spectral radiance, chromaticity, and correlated color temperature measurements.

PC-driven testing

USB 2.0, RS-232C, and CS-900A support legacy control and data recording.

HDR and OLED Black-Level Research

Measure very low luminance levels during display contrast evaluation.

LCD and OLED Color Testing

Characterize spectral radiance and chromaticity in display development.

Automotive Cockpit Displays

Verify low-brightness indicators, panel lights, and display elements.

Digital Signage Evaluation

Inspect luminance and spectral characteristics of signage modules.

Production-Line Optical QA

Apply repeated spot tests where measurement timing and environment permit.

Replacement Specification Planning

Compare a legacy SR-UL2 measurement setup against new SR-5A configurations.

Product statusDiscontinued; manufacturer successor SR-5A
Instrument typeUltra-low-luminance spot spectroradiometer
Wavelength range380–780 nm
Half-bandwidth5–8 nm
Wavelength resolution1 nm
Wavelength accuracy±0.3 nm, Hg lamp reference
Photo detectorElectronically cooled linear CCD
Observation angles2°, 1°, 0.2°, 0.1°; motor selectable
Working distance350 mm to infinity
Luminance accuracy±2% or less under manufacturer conditions
Chromaticity accuracy±0.002 under manufacturer conditions
Operating modesNORMAL, HIGH SPEED; auto/manual
Measurement timeApprox. 1–248 s normal; 1–17 s high-speed, conditions apply
InterfacesUSB 2.0 / RS-232C
Power consumptionApprox. 36 W
Dimensions (W × D × H)150 × 406 × 239 mm
WeightApprox. 5.5 kg

Measurement angle2°1°0.2°0.1°
Luminance range (cd/m²)0.0005–3,0000.0015–9,0000.0375–70,0000.15–300,000

The 0.0005 cd/m² minimum applies only at 2°; 300,000 cd/m² applies at 0.1°. Measurement time examples exclude PC communication.

Manufacturer source: https://www.techno-optis.com/en/products/sr-ul2/