Home » Electronic Measuring Instruments » Signal Generators & Analyzers » Power Quality Analyzer » KIKUSUI KHA3000 Three-Phase Harmonic/Flicker Analyzer

KIKUSUI KHA3000 Three-Phase Harmonic/Flicker Analyzer

KIKUSUI
Supplier / Manufacturer: KIKUSUI
Model: KHA3000

Contact Us

Three-Phase Harmonic and Flicker Compliance Testing up to 40 A per Phase

The KIKUSUI KHA3000 is a high-current harmonic and flicker analyzer designed for simultaneous three-phase and single-phase testing of electrical and electronic equipment against applicable IEC, EN, and JIS harmonic-current and voltage-fluctuation requirements.

Three voltage and three current measurement channels support single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, and three-phase 4-wire systems. Direct current measurement is available up to 40 Arms per phase, making the KHA3000 suitable for equipment above the 16 A range as well as lower-current products.

40 A / Phase Direct simultaneous three-phase current measurement
3-Phase / 1-Phase Supports four common AC wiring configurations
40th / 180th Harmonic Harmonic analysis through the 40th order in HA mode and 180th order in OTHER mode
Standalone Testing Run tests, evaluate results, and generate reports without a PC

In addition to standards-based harmonic and flicker testing, the KHA3000 provides voltage, current, power, power factor, apparent power, reactive power, frequency and phase measurement, waveform monitoring, FFT analysis, and inrush-current measurement. GPIB, RS232C, and USB interfaces are standard for integration with automated measurement systems.

Simultaneous Three-Phase Measurement

Three voltage and three current channels measure L1, L2, and L3 simultaneously. For long-term three-phase flicker evaluation, simultaneous measurement can substantially reduce total test time compared with measuring each phase separately.

Up to 40 A per Phase Direct Measurement

Seven current ranges from 0.5 A to 40 A support direct measurement of equipment requiring higher phase current. Measurement above 40 A per phase can be configured using supported external current sensors.

Harmonics and Interharmonics Analysis

Supports harmonic-current analysis through the 40th order in compliance-test mode and through the 180th order in general analysis mode, with selectable interharmonic processing according to the applicable IEC 61000-4-7 measurement method.

Flicker and Voltage-Fluctuation Testing

Measures short-term flicker and voltage-fluctuation parameters with real-time waveform and result displays for applicable IEC 61000-3-3 and IEC 61000-3-11 testing.

FFT and Inrush-Current Measurement

Built-in FFT analysis, V/I waveform monitoring, and inrush-current measurement support development and troubleshooting in addition to formal compliance testing. Direct inrush-current measurement reaches 160 Apeak for up to 20 ms.

Standalone Compliance Testing and Reports

Test setup, execution, limit judgment, spectrum review, and result-report generation can be performed directly on the KHA3000. Reports are available in PDF and text formats without requiring a PC for normal test operation.

Three-phase equipment harmonic-current compliance testing
Single-phase equipment harmonic and flicker testing
Equipment above 16 A per phase under IEC 61000-3-12 requirements
Voltage fluctuation and flicker testing under applicable IEC 61000-3-3 / 61000-3-11 requirements
Inrush-current and AC input waveform evaluation during product development
Pre-compliance and standards-based power quality emission testing

KHA3000 Specifications

Measurement Configuration Three voltage channels and three current channels: L1, L2, L3
Supported Wiring Single-phase 2-wire / single-phase 3-wire / three-phase 3-wire / three-phase 4-wire
Maximum Input Voltage 600 Vrms / 900 Vpeak (CAT I), 400 Vrms (CAT II)
Voltage Ranges 150 V / 300 V / 600 V
Voltage Accuracy ±(0.4% of reading + 0.04% of range)
Maximum Direct Input Current 40 Arms / 100 Apeak, whichever is smaller
Short-Duration Peak Current 160 Apeak within 20 ms
Current Ranges 0.5 A / 1 A / 2 A / 5 A / 10 A / 20 A / 40 A
Fundamental Frequency Measurement 45 Hz to 65 Hz
Frequency Resolution 0.001 Hz
Power Measurements Active power, apparent power, reactive power, and power factor
Phase Measurement Voltage/current phase, line-voltage phase, and harmonic phase
Phase Range / Resolution 0.00° to 359.99° / 0.01°
Harmonic Analysis Order 40th order in HA mode / 180th order in OTHER mode
Voltage Harmonic Analysis Through the 40th order
Pst Accuracy 1 ±5%
Pst Measurement Time 30 to 900 s
General Measurement Functions V/I waveform monitor, FFT analyzer, and inrush-current measurement
Standard Interfaces GPIB / RS232C / USB
Removable Storage CF card up to 512 MB / USB memory up to 16 GB
AC Input 100 V to 240 V AC, 50 Hz to 60 Hz
Dimensions 430 W × 177 H × 270 D mm
Weight Approx. 10 kg

Harmonic Current Standards

IEC 61000-3-2 Supports IEC 61000-3-2 Ed5.0 (2018), Ed3.0 (2005), and Ed2.2 (2004) harmonic-current limit testing.
IEC 61000-3-12 Supports IEC 61000-3-12 Ed2.0 (2011) and Ed1.0 (2004) for applicable equipment above 16 A and up to 75 A per phase.
IEC 61000-4-7 Measurement methods support IEC 61000-4-7 Ed2.1 (2009), Ed2.0 (2002), and Ed1.0 (1991).
JIS C 61000-3-2 Supports JIS C 61000-3-2 (2019) and (2005).


Flicker & Voltage-Fluctuation Standards

IEC 61000-3-3 Supports IEC 61000-3-3 Ed3.1 (2017) and Ed2.0 (2008) for applicable low-current equipment.
IEC 61000-3-11 Supports IEC 61000-3-11 Ed2.0 for applicable equipment above 16 A and up to 75 A per phase.
IEC 61000-4-15 Flicker measurement methods support IEC 61000-4-15 Ed2.0 (2010) and Ed1.1 (2003).
Flicker Measurement Pst accuracy: 1 ±5%; selectable measurement time from 30 to 900 s
Voltage-Fluctuation Measurement Can be measured simultaneously with Pst or independently, including dmax measurement for manually switched equipment.


Three-Phase Measurement Functions

Measurement Channels L1 / L2 / L3 voltage and current channels
Channel Range Control Independent voltage/current ranges with AUTO range capability for each channel
Channel Setting L1, L2, and L3 settings can be interlocked or configured independently
Supported Wiring 1φ 2-wire / 1φ 3-wire / 3φ 3-wire / 3φ 4-wire
Three-Phase Flicker All three phases can be measured simultaneously
Vector Display Three-phase vector phase display available


Development & Diagnostic Measurements

FFT Analyzer Built-in
Waveform Monitoring Voltage and current waveform monitoring
Inrush Current Up to 160 Apeak with direct input for up to 20 ms
Inrush Voltage Monitoring Voltage waveform can be observed together with inrush current
Harmonic Display 2D / 3D harmonic views, THC, harmonic-current trend, and harmonic list
Basic Power Measurements Voltage, current, active power, apparent power, reactive power, power factor, and frequency


Standalone Testing & Report Output

Standalone Test Setup Supported from the KHA3000 front panel
Test Execution Can be performed without a connected PC
Real-Time Judgment Standards-based pass/fail results and spectrum data displayed during testing
Report Creation Test-result reports can be prepared without a PC
Report Formats PDF and text
Data Storage CF card and USB memory
Optional PC Software SD006-KHA Harmonics Analyzing Suite


Interfaces & System Integration

Standard Interfaces GPIB / RS232C / USB
External AC Source Control PCR-LE / LE2 Series control through RS232C
Controllable AC Source Parameters Voltage, frequency, range, ON phase, and output ON/OFF
System Software SD006-KHA Harmonics Analyzing Suite
Line Impedance Network KIKUSUI LIN Series available for applicable standards-based system configurations
Daily System Check Optional OP02-KHAS pre-test checker