OVAL Psonic-L4 Four-Path Ultrasonic Liquid Flowmeter

Four-path transit-time ultrasonic flowmeter for oil and other suitable homogeneous liquids, with bidirectional metering and self-diagnostics.

The OVAL Psonic-L4 uses four parallel ultrasonic measurement paths to measure the flow of oil, heavy oil and other homogeneous liquids that transmit ultrasound. The path architecture supports long-term measurement stability and can reduce downtime through supplemental processing if a sensor experiences a fault.

It is designed for petroleum-product transfer, pipeline measurement and bulk liquid measurement where flow traceability is important. The meter supports flow velocity from −10 to +10 m/s and nominal pipe sizes of 100 to 300 mm, with suitable flanged process connections.

Standard factory-calibration accuracy is ±0.5% of reading. The improved ±0.15% of reading specification requires high-accuracy calibration under qualifying installation and flow conditions, including matching Reynolds-number conditions and appropriate upstream/downstream runs. Hazardous-area approvals and the IP66 enclosure rating depend on the selected configuration.

4 pathsParallel ultrasonic flow measurement
100–300 mmFive nominal pipe sizes
±0.15% RDHigh-accuracy calibration only
±10 m/sBidirectional measurement range

Four-path measurement architecture

Parallel ultrasonic paths support stable velocity estimation and measurement redundancy.

Bidirectional flow measurement

Measures positive and negative liquid-flow velocities in either direction.

Custody-transfer applications

Supports high-traceability petroleum transfer under verified calibration conditions.

No strainer required

Manufacturer states that a separate strainer is not required for the stated meter design.

Extensive self-diagnostics

Status checks support troubleshooting of the metering system and sensor condition.

Calibrated high-accuracy option

±0.15% of reading is available with the required high-accuracy calibration and installation.

Petroleum Product Custody Transfer

Measure oil or refined products with appropriate accredited calibration.

Oil Pipeline Measurement

Monitor bidirectional liquid transfer in petroleum pipelines.

Marine Loading and Unloading

Meter suitable liquid product transfers at loading facilities.

FPSO and FSO Product Transfer

Support flow measurement during storage and offloading operations.

Refinery Process Measurement

Measure compatible liquid petroleum streams in industrial process systems.

Bulk Liquid Flow Monitoring

Collect self-diagnostic information for large-diameter liquid lines.

SpecificationDetails
Working principleTransit-time measurement using four parallel ultrasonic paths
Applicable fluidsOil, heavy oil and other homogeneous liquids transmitting ultrasound
Nominal pipe sizes100, 150, 200, 250, 300 mm
Measurement paths4
Flow velocity range−10 to +10 m/s
Standard accuracy±0.5% of reading (RD), with qualifying calibration and upstream/downstream runs
High-accuracy calibration±0.15% of reading (RD), with matched-Reynolds-number calibration and qualifying installation
Fluid temperature−20 to +120°C
Design pressure8 MPa at 120°C; actual maximum operating pressure depends on flange rating
FlangesJIS 10/20/30K RF, JPI 150/300 RF, ASME 150/300 RF
Enclosure / approvalsIP66; TIIS/ATEX explosion-proof configurations listed by manufacturer

The ±0.15% reading value is NOT the standard calibration. Standard accuracy is ±0.5% RD. The high-accuracy figure is contingent on specified calibration matching the operating Reynolds number and suitable piping (manufacturer describes upstream 10D with straightener and downstream 5D). Confirm approvals, operating pressure, fluid and installation for the exact order.