OVAL FLM Eggs DELTA II Vortex Flow Monitor

OVAL Eggs DELTA II FLM Compact Vortex Flow Monitor

Monitor small utility lines with a compact vortex flowmeter that combines local readings and selectable flow-monitoring outputs.

The OVAL Eggs DELTA II, identified by the manufacturer as FLM, uses the Karman vortex measuring principle in a compact resin-bodied instrument. Its intended applications include utility-fluid consumption tracking and flow supervision at the point of use on production equipment.

Four nominal sizes (4, 8, 15 and 25 mm) cover water flow ranges from 0.4–4 to 8.3–133 L/min and gas ranges from 7.2–17 to 167–850 L/min. These values belong to different nominal diameters, so an installation must be sized by medium and operating conditions rather than the overall envelope alone.

A local LCD makes the FLM useful for operators who need an at-a-glance view of flow at the instrument. OVAL supplies DC- and battery-powered options, and its product table lists analog and pulse outputs for flow and alarm duties; available signal formats depend on the ordered variant.

The general specifications describe a non-explosionproof, IP53-equivalent design. For pulse-only integration without a local display, compare the related Eggs DELTA Pulse FLP, which uses a different electrical and enclosure specification.

4 / 8 / 15 / 25 mm Available nominal connection sizes
0.4–133 L/min Liquid flow family envelope
7.2–850 L/min Gas flow family envelope
IP53 equivalent Published enclosure rating

Compact Vortex Flow Monitoring

Measure small-volume utility flows in a light-duty instrument designed for point-of-use installation.

Local Readout

View flow information on the installed monitor without needing a separate receiving instrument for basic visual checks.

Four Nominal Sizes

Select 4, 8, 15 or 25 mm based on water or gas flow range and process connections.

Liquid and Gas Compatibility

Use approved configurations for cooling water, pure water, air and nitrogen at the published temperature and pressure limits.

No Moving Measuring Parts

The vortex measurement principle reduces mechanical wear from moving meter components; OVAL highlights dust and mist resistance.

Flexible Power and Outputs

Select battery or DC versions, with analog or pulse flow/alarm outputs as supported by the specific configuration.

Cooling Water Branch Lines

Check circulation and consumption of cooling water in small industrial utility loops.

Pure Water Supply Monitoring

Track flow to manufacturing or laboratory equipment using compatible pure-water service.

Compressed-Air Consumption

Monitor air usage at individual machines or production stations when gas conditions suit the sensor range.

Nitrogen Supply Lines

Follow nitrogen consumption in compatible process and purge lines without a large industrial meter.

Machine Utility Monitoring

Integrate flow readings with on-machine monitoring and control systems through compatible outputs.

Energy and Resource Management

Collect utility-flow information for site-level efficiency and usage-management programs.

OVAL Eggs DELTA II FLM Compact Vortex Flow Monitor Specifications

Product / manufacturer modelEggs DELTA II / FLM
TechnologyKarman vortex flow-monitoring principle
Nominal pipe sizes4, 8, 15 and 25 mm
Liquid ranges, 4 / 8 mm0.4–4 / 1.1–15 L/min
Liquid ranges, 15 / 25 mm2.8–45 / 8.3–133 L/min
Gas ranges, 4 / 8 mm7.2–17 / 18–90 L/min
Gas ranges, 15 / 25 mm55–283 / 167–850 L/min
Applicable liquidsCooling water and pure water, subject to operating conditions
Applicable gasesAir and nitrogen, subject to operating conditions
Accuracy, liquids±2% of full scale
Accuracy, gases±3% of full scale
Max. operating pressure0.98 MPa
Operating fluid temperature−10 to +80°C
Process connectionsR male (resin), Rc female (metal) and NPT male (resin), variant-specific
Body materialPPS resin (polyphenylene sulfide)
DisplayLocal LCD monitor; display functions depend on meter configuration
Enclosure protectionIP53 equivalent; non-explosionproof per general product specification
Power optionsDC-powered or battery-powered
OutputsAnalog and pulse (flow / alarm), according to ordered configuration
Compared related modelFLP Eggs DELTA Pulse: no local display; pulse-only, DC-powered, IP65

Model and Size Comparison

Nominal size4 mm8 mm15 mm25 mm
Liquid flow (L/min)0.4–41.1–152.8–458.3–133
Gas flow (L/min)7.2–1718–9055–283167–850

The four flow ranges are size-specific. Unlike the related FLP, this FLM listing has a local display and an IP53-equivalent general enclosure rating. Choose the correct connector, supply and output style at quotation. The manufacturer page lists applicable liquid and gas media; do not promise unrestricted steam service based only on a site category icon.