ATSENSE TFW-200 / TFM-200 Flow Meter

ATSENSE
Supplier / Manufacturer: ATSENSE
Model: TFW-200 / TFM-200

Industries & Applications:
Contact Us

Twin Digital Flow Meter TFW/TFM-200

The ATSENSE TFW-200 and TFM-200 are high-performance twin digital panel meters designed for engine R&D and test systems. The TFW-200 measures both instantaneous and total fuel flow, while the TFM-200 provides dual-channel instantaneous flow measurement with A/B sensor support. Featuring a two-level LCD, CAN output, and a wide range of analog, digital, and communication interfaces (USB, RS-232/485), these meters enable simultaneous measurement, averaging, and repeat integration. With fast 1 ms analog output, IP66 front protection, and flexible configuration, the TFW/TFM-200 ensures precise and efficient fuel flow monitoring.
  • The first panel meter that has been used for CAN data output (option)
  • 6-digit and 13-digit, two-level, high brightness LCD display (red and green). You can choose the display color.
  • A multitude of options (analog output/BCD output/CAN output/contact output/RS232 communication/RS485 communication/USB communication)

【High-performance functions】
The functions and performance of the flow rate meter have been incorporated into the panel meter. Analog output is at a high speed of 1ms.


And you can choose from a multitude of output options to use

〇 Instantaneous flow and total flow can be measured simultaneously 〇 As well as the real total flow, you can also measure the average flow over any given period 〇 Both flow sensors (A, B) can be measured at the same time, and the display and analog signal for each can be output as desired 〇 The combinations A+B, A-B, and the average flow can also be measured as either the instantaneous or the total flow 〇 An auto-repeat measurement is possible in which integration commences when “Start” is entered, and the display and output refreshed after a set time has elapsed, and this then repeated until “Stop” is entered.

The model configuration of the TFW-200 and TFM-200 is shown in the figure below.
When option “No” was selected the model configuration is left-justified.
Multiple options of the same option group cannot be selected.
Two types of output can be selected from among digital output, contact output, and communication.

ModelTFW-200TFM-200
NameInstantaneous and total flow meterInstantaneous flow meter
Arithmetic
Input operationsA/AB (reversible)/A+B/A-B/AB average
Instantaneous measurementMeasurement methodPeriodic calculation method (with function for predicting deceleration)
Measurement clock20MHz
Total measurementMeasurement methodScaling integration
Integration methodFree/timer stop/timer repeat
Operation key5 points Separate function at measurement/setting
MemoryMemory elementNon-volatile memory
Memory contentSetting values and total flowSetting values
Display
DisplayLCD negative, backlight
Main displayDisplay itemsInstantaneous flow
Display color, character height, number of digitsSwitching between red and green backlight, 14.2mm, 6 digits + polarity (-)
Sub-displayDisplay itemsTotal flow (TFW-200 only)/comparator setting values/Instantaneous flow A – B/OFF
Display color, character height, number of digitsSwitching between red and green backlight, 6.5mm, 13 digits + polarity (-) at 2 points
Status displayDisplay colorSwitching between red and green backlight
Instantaneous measurementRefresh time0.1 to 9.9s
Moving average1 to 99
Signal input (sensor input)
Number of inputs2 inputs
Types of input signal (CH)Single-phase (2ch) / UP/DOWN (1ch) / A/B 2-phase signal (1ch) switching
Maximum input frequencySingle-phase, UP/DOWN signal100kHz
A/B 2-phase signal60kHz
Minimum input frequency0.005Hz (only for measurement of instantaneous flow)
Frequency division (pulse average)Signal A only, 1 to 999
Signal input (sensor input) (0) General purpose
Input levelAC (zero-cross) signal±200mV to ±30V, LPF switching
Signal A
Logic signalH level 3.9V or more, L level 1V or less (voltage resistance ±30V)
OthersPull-up/pull-down switching
Power supply for sensorVoltage and maximum currentDC12V±10%, 100mA
External control inputNumber of points2 points
Signal typeContact/TTL (minimum pulse width 5ms)
ItemsStart/Stop/Reset/Hold switching
Analog output
Refresh time0.001 to 9.999s
D/A conversion16bit
Analog output (V) General purpose (1CH)
Number of outputs1 output
Output itemsInstantaneous flow/total flowInstantaneous flow
Output rangeVoltage output range±10/0-10/0-5/1-5 V (load of 4.7kΩ or more)
Current output range4-20mA (load of 560Ω or less)
AccuracyVoltage output ±0.1%F.S. or less/current output ±0.2% F.S. or less (23℃)/temperature variation ±200ppm/℃ or less
Analog output (W) Voltage (2CH)
Number of outputs2 outputs
Output itemsInstantaneous flow/total flowInstantaneous flow
Output rangeVoltage output range±10V (load of 4.7kΩ or more)
AccuracyVoltage output ±0.1%F.S. or less (23ºC)/temperature variation ±200ppm/ºC or less
Contact output (C) Contact output (photo MOS relay), (O) Contact output (open collector)
Number of outputs4 outputs
Refresh timeAnalog synchronization/display synchronization switching
Output itemsComparator/unit pulse switching
Unit pulse rate, maximum frequency0.1 to 9999.9mL/P, 1kHz
Output circuit(C) Photo MOS relayMaximum load voltage (peak AC/DC) 350V, continuous load current (peak AC/DC) 80mA, output ON resistance 35Ω (typical)
(O) Open collector NPN open collector, maximum load voltage 30V, maximum load current 15mA
Communication (4) RS-485 (2) RS-232 (U) USB
Communication formatSerial communication(4) RS-485/(2) RS-232/(U) USB
Communication speed9.6k/19.2k/38.4k bps
Data length7/8 bit
Parity bitNull/even/odd
Stop bit1/2 bit
Character codeASCII
Digital output
Output itemsInstantaneous flow/total flowInstantaneous flow
Refresh timeAnalog synchronization/display synchronization switching
Digital output (T) BCD output (TTL), (P) BCD output (open collector)
Number of output digits6 digits + polarity
Output circuit(T) TTLOutput voltage 0-5V (output current ± 100mA, but ± 4mA/ch)
(P) Open collector NPN open collector, maximum load voltage 30V, maximum load current 20mA/ch
Digital output (N) CAN
Output circuitCAN2.0B complianceHigh-Speed CAN (ISO11898-2)
Communication speed1Mbps/500kbps/250kbps/125kbps
Data formatLittle endian/Big endian
ID lengthStandard 11bit/Extended 29bit
Data formatSigned long (4 bytes)
Output refresh timeDigital output refresh time/1/2/5/10ms
General specification
Supplied power sources(A) Power supply (AC)AC100 to 240V ±10% (50/60Hz), (100V, 18VA or less, 240V, 24VA or less)
(D) Power supply (DC)DC12 to 24V ±10% (10W or less)
Electrical insulationInsulation rangeSensor input – analog output – contact output – communication and digital output – supplied power sources
Protective structureFront panel IP66
Operating temperature and humidity range0 to 50℃, 85%RH or less (with no condensation)
External dimensions, WeightW: 96 H: 48 D: 100 (D: 93 inside part)
Approx. 230g (when equipped with all options)