ATSENSE FS-1213 / FS-1214 Fuel Flow Detector

High-Accuracy Fuel Flow Detection with Low Pressure Loss

The ATSENSE FS-1213 and FS-1214 are positive-displacement fuel flow detectors for engine R&D, combining high flow resolution, bidirectional pulse measurement and integrated 10 μm filtration.

The FS-1213 measures 0.06–108 L/h and the FS-1214 measures 0.3–600 L/h in the English-language manufacturer specification. Both list flow accuracy within ±0.2% of reading and operate with a maximum fluid pressure of 1 MPa.

±0.2% RD Specified flow reading accuracy
0.06–600 L/h Combined model coverage
10 μm Integrated reusable mesh filter
A/B Pulses Forward/reverse flow detection

A radial-piston measurement mechanism and low-pressure-loss flow path make the FS Series suitable for accurate flow measurement in fuel lines, including returnless systems. A/B phase pulses allow the downstream instrument to detect forward and reverse flow.

An optional temperature sensor and pressure sensor expand the measurement configuration. Fuel compatibility depends on the selected gasoline/light-oil or alcohol-compatible version, so specify fuel type and operating conditions when requesting a quotation.

Two Flow-Range Models

FS-1213 covers 0.06–108 L/h, while FS-1214 extends coverage to 0.3–600 L/h.

High Flow Measurement Accuracy

The manufacturer specifies accuracy within ±0.2% of reading for both detectors.

High Pulse Resolution

Provides 0.001 mL/pulse for FS-1213 and 0.011 mL/pulse for FS-1214.

Low Pressure Loss

The sensor and filter assembly allows fuel-line measurements that approximate actual operating conditions.

Bidirectional Pulse Measurement

A/B-phase signal information permits recognition of forward and reverse flow events.

Optional Additional Sensing

Compatible configurations can incorporate pressure and temperature sensing for expanded fuel-system monitoring.

Automotive Engine Development

Measure fuel flow across varying engine loads and operating conditions.

Low-Flow Fuel Measurement

Characterize low fuel consumption during idle and low-load operation.

Returnless Fuel-System Testing

Insert a low-pressure-loss detector in a fuel line with minimal disturbance to operating conditions.

Fuel Supply and Return Monitoring

Use separate detectors in a two-line arrangement for differential fuel-consumption studies.

Biofuel and Alcohol Evaluation

Select an alcohol-compatible configuration for relevant fuel research.

Test-Bench Data Acquisition

Connect A/B-phase pulse signals to compatible fuel meters or data acquisition systems.

Specification FS-1213 FS-1214
Flow Range 0.001–1.8 L/min (0.06–108 L/h) 0.005–10 L/min (0.3–600 L/h)
Flow Accuracy Within ±0.2% of reading Within ±0.2% of reading
Minimum Pulse Resolution 0.001 mL (1,000 pulses/mL) 0.011 mL (90 pulses/mL)
Maximum Operating Pressure 1 MPa 1 MPa
Operating Fluid Temperature −40 to +80°C −40 to +80°C
Fluid Connection Rc 1/4 Rc 3/8
Filter 10 μm stainless-steel mesh 10 μm stainless-steel mesh
Case Material A5052 A5052
Sensing Parts SUS303, SUS440C SUS303, SUS440C
Fittings SUS304 SUS304
Dimensions (Excluding Projections) W120 × H208 × D70 mm W225 × H250 × D130 mm
Approx. Weight 2.6 kg 6.5 kg
Optional Sensors Temperature and pressure Temperature and pressure
Output Characteristics Bidirectional flow pulse signal Bidirectional flow pulse signal

The English ATSENSE product page and the uploaded Denkei export list 0.06 L/h as the FS-1213 minimum and −40°C as fluid-temperature minimum. The current Japanese manufacturer page differs (0.03 L/h and −20°C). Confirm the applicable specification revision and selected configuration before publishing updated limits or quoting.