Home » Electronic Measuring Instruments » Data Loggers & Data Acquisition » Fuel Flow Meter » ATSENSE FDM-700 / FDM-720 Fuel Flow and Density Meter

ATSENSE FDM-700 / FDM-720 Fuel Flow and Density Meter

Real-Time Fuel Flow, Density and Mass Flow Measurement

The ATSENSE FDM-700 / FDM-720 Series calculates and displays fuel flow, density, mass-converted flow, temperature and pressure using compatible detector inputs for engine research and fuel consumption testing.

The meters accept signals from compatible FDS flow-and-density detectors or FS flow detectors together with DM-200 density detection. They display instantaneous flow, integrated and interval flow, density, temperature and pressure on a 480 × 272 color LCD.

1 / 2 Detector inputs: 700 / 720
0.5 / 1 ms Flow/pressure analog refresh
8 Analog outputs
480 × 272 Color LCD resolution

FDM-700 provides one flow/density detector input, while FDM-720 provides two inputs and supports inter-channel calculations. Analog output refresh for instantaneous flow and pressure is 0.5 ms on the FDM-700 and 1 ms on the FDM-720.

With compatible sensor selection, the system supports low-flow measurements during idle and low-load engine operation, as well as transient measurement, temperature correction and volume-to-mass conversion. Sensor accuracy and measurement resolution depend on the connected detector.

Multi-Parameter Fuel Measurement

Displays instantaneous and accumulated flow, mass-converted data, density, temperature and pressure.

One- or Two-Input Selection

FDM-700 uses one detector input; FDM-720 supports two with inter-channel calculation.

Fast Analog Output

Updates flow and pressure output every 0.5 ms on the 700 or 1 ms on the 720.

Flow and Density Integration

Combines compatible sensor data for temperature correction and mass-flow conversion.

Flexible Reporting and Control

Provides selectable measurement screens, integrated runs, data memory and RS-232C communication.

Analog and Pulse Interfaces

Offers eight configurable analog outputs and four pulse outputs for test system integration.

Engine Fuel Consumption Testing

Track instantaneous and accumulated fuel usage during controlled engine tests.

Idle and Low-Load Flow Monitoring

Observe small flow changes with a compatible high-resolution detector.

Transient Fuel Flow Analysis

Capture rapid fuel-flow and pressure changes through the analog interface.

Fuel Mass Flow Conversion

Calculate mass-based flow using measured volumetric flow and density.

Density and Temperature Evaluation

Monitor fuel properties and perform temperature-related volume correction.

Two-Channel Fuel System Studies

Use FDM-720 detector inputs and inter-channel calculation in compatible two-channel configurations.

SpecificationFDM-700FDM-720
Detector input channels12
Inter-channel calculationNot supportedSupported
Instantaneous flow/pressure analog refresh0.5 ms1 ms
Density/temperature analog refresh1 s1 s
ScreenColor LCD, 480 × 272Color LCD, 480 × 272
Display layout2, 4, 6 or 12 items2, 4, 6 or 12 items
Analog outputs8, BNC8, BNC
Analog resolution16-bit D/A16-bit D/A
Analog range±10 V±10 V
Analog accuracy±0.1% F.S. at 23°C ±5°C±0.1% F.S. at 23°C ±5°C
Pulse outputs4, BNC4, BNC
Integrated pulse unit selection0.001 / 0.01 / 0.1 / 1 mL (g) per pulse0.001 / 0.01 / 0.1 / 1 mL (g) per pulse
Data memory100 addresses, rolling100 addresses, rolling
CommunicationRS-232C, D-sub 9-pinRS-232C, D-sub 9-pin
Power supply9–32 V DC; ≤20 W9–32 V DC; ≤20 W
WeightApprox. 1.7 kgApprox. 1.7 kg
Operating conditions0–40°C; ≤85% RH, non-condensing0–40°C; ≤85% RH, non-condensing
Common SpecificationFDM Series
Compatible detectorsFDS fuel flow/density series; FS fuel flow series; DM-200 density detector
Measurement parametersInstantaneous and average flow, integrated flow, time, density, temperature and pressure
Temperature correctionCorrects volumetric flow to a reference temperature
Mass conversionCalculated from volumetric flow and detected density
Display update intervalsDensity/temperature: 1 s; time/integrated flow: 0.1 s; flow/pressure display: configurable 0.1–10 s
Integrated measurement modesOne-time, interval or continuous integration
Integrated stopping conditionsManual, integration time or accumulated volume
Analog output load≥4.7 kΩ
Pulse logic level0–5 V
External integration control1 start/stop input