Home » Manufacturing / Processing / Inspection Equipment » Motor & Drivetrain Testing » Fuel Flow Meter » ATSENSE FDS-1213 / FDS-1214 Fuel Flow and Density Detector

ATSENSE FDS-1213 / FDS-1214 Fuel Flow and Density Detector

Integrated Fuel Flow, Density, Temperature and Pressure Detection

The ATSENSE FDS-1213 and FDS-1214 integrate fuel flow, density, temperature and pressure sensors with a 10 μm filter for engine test benches and fuel-system research.

The FDS-1213 covers 0.06–108 L/h and the FDS-1214 covers 0.3–600 L/h. The manufacturer specifies flow accuracy of ±0.20% of reading over 0.6–108 L/h and 6–600 L/h, respectively. Both models generate A/B-phase flow pulses for downstream measurement instruments.

0.06–108 L/h FDS-1213 measurement range
0.3–600 L/h FDS-1214 measurement range
±0.001 g/cm³ Specified density uncertainty
4 Sensors Flow, density, temperature and pressure

Integrated sensing makes it possible to measure fuel volume flow and simultaneously observe density, liquid temperature and line pressure. A 10 μm filter and low-pressure-loss sensor arrangement simplify placement in a test-bench fuel line.

Pair the detector with a compatible ATSENSE FDM Series flow and density meter for instantaneous flow, converted mass flow, totalized flow and synchronized fuel-property readings. Gasoline/light-oil and alcohol-compatible configurations are specified separately.

Integrated Four-Parameter Sensing

Combines volumetric flow, density, temperature and pressure measurement points in one fuel-line detector assembly.

Two Flow-Capacity Options

Choose FDS-1213 for 0.06–108 L/h or FDS-1214 for 0.3–600 L/h measurement range.

Specified Flow Measurement Accuracy

Provides ±0.20% of reading accuracy within the manufacturer-defined 0.6–108 L/h or 6–600 L/h accuracy range.

Density and Temperature Monitoring

Measures liquid density from 0.5 to 2 g/cm³ with ±0.001 g/cm³ uncertainty, plus temperature from 5 to 60°C.

Integrated 10 μm Filtration

A built-in stainless-steel mesh filter and low-pressure-loss sensing assembly reduce the need for additional fuel-line components.

Compatible with FDM Meters

Connect to an ATSENSE FDM Series display/processing unit to calculate mass flow and monitor multiple fuel parameters.

Engine Fuel-Consumption Development

Evaluate volumetric and density-compensated fuel flow on engine development benches.

Fuel Density Characterization

Monitor density changes during comparative measurements of different liquid fuels.

Fuel-Line Pressure Monitoring

Observe line pressure alongside flow and temperature during controlled testing.

Gasoline and Diesel Fuel Evaluation

Use the appropriate fuel-compatible configuration for gasoline and light-oil measurements.

Alcohol-Compatible Fuel Testing

Select the manufacturer-specified alcohol-compatible variant for relevant fuel research.

Integrated Test-Bench Data Acquisition

Feed sensor signals to an FDM meter for multi-parameter fuel data capture.

Specification FDS-1213 FDS-1214
Fuel Flow Range 0.06–108 L/h 0.3–600 L/h
Flow Accuracy (Specified Range) ±0.20% of reading (0.6–108 L/h) ±0.20% of reading (6–600 L/h)
Flow K-Factor 500 pulses/mL 45 pulses/mL
Flow Signal 0–5 V A/B-phase pulses; 90° phase difference; 10 mA max 0–5 V A/B-phase pulses; 90° phase difference; 10 mA max
Pressure Range 0–1 MPa 0–1 MPa
Pressure Output 1–5 V 1–5 V
Pressure Accuracy Nonlinearity ±0.5% FS; hysteresis ±0.5% FS Nonlinearity ±0.5% FS; hysteresis ±0.5% FS
Density Range 0.5–2 g/cm³ 0.5–2 g/cm³
Density Uncertainty ±0.001 g/cm³ ±0.001 g/cm³
Temperature Range 5–60°C 5–60°C
Temperature Accuracy ±0.1°C ±0.1°C
Fluid Couplings Rc 3/8 Rc 3/8
Pressure Rating 1 MPa 1 MPa
Filter 10 μm stainless-steel mesh 10 μm stainless-steel mesh
Casing SUS304 SUS304
Operating Ambient Temperature 10–40°C 10–40°C
Approx. Weight (H / D Types) 8 / 7 kg 14 / 11 kg
Replacement Filter Set MK-010 MK-010

The ±0.20% flow accuracy applies only within the stated accuracy ranges, not necessarily the full flow ranges. H/D weight figures depend on configuration. Gasoline/light-oil and alcohol-compatible versions must be specified when ordering. English-language supplier data are used for these model ranges; confirm latest revisions before quotation.