ATSENSE FM-110 Flow Meter

Single-Detector Fuel Flow Meter with 1 ms Analog Output

The ATSENSE FM-110 measures instantaneous flow, time-averaged flow and totalized fuel flow from one connected detector for engine development and vehicle testing.

The meter updates instantaneous-flow analog output every 1 ms, helping engineers observe rapid changes in fuel consumption during throttle operation. Its LCD supports several measurement screens and timed integration functions for repeated test sequences.

1 ms Instantaneous-flow analog update
1 Detector Single fuel-flow sensor input
5 Outputs Simultaneous analog measurement outputs
USB + Pulse Digital logging and total-flow pulses

The FM-110 offers up to five simultaneous analog outputs for flow quantities and, when compatible sensors are fitted, temperature and pressure. USB mini-B communicates displayed values to a connected PC, while pulse output supports fuel-volume totalization.

Operators can configure automatic timed measurement, switch among monitoring views and use key lock to prevent accidental changes. Flow accuracy at the system level depends on the connected detector; meter-only accuracy must not be interpreted as complete measurement-system accuracy.

Three Fuel Flow Measurements

Measures instantaneous, time-averaged and totalized fuel flow for different test objectives.

1 ms Instantaneous Analog Updates

Provides rapid analog output to capture transient fuel-consumption changes during engine operation.

Five Analog Output Channels

Outputs flow quantities plus temperature and pressure when the connected detector provides those signals.

USB and Volume Pulse Output

Transfers displayed values to a PC by USB mini-B and provides a pulse output for fuel-volume integration.

Timed Automatic Test Cycles

Supports repeatable integration-time measurement and review of recent totalized results.

Compact Vehicle-Use Format

Runs from 9–32 V DC and combines key lock with a compact 140 × 40 × 100 mm housing.

Engine Test-Bench Fuel Flow

Monitor instantaneous and accumulated fuel consumption during dynamometer testing.

Throttle-Response Evaluation

Compare changes in fuel flow with accelerator input using the 1 ms analog output.

Vehicle Fuel-Consumption Testing

Connect a suitable detector to collect flow data during vehicle development.

Timed Fuel-Use Measurement

Run repeated average-flow measurements over specified test intervals.

Fuel-Line Temperature and Pressure

Record optional temperature and pressure signals alongside flow measurement.

Data Logging and Test-System Integration

Send analog, pulse or USB data to monitoring and acquisition equipment.

Specification FM-110
Sensor Inputs 1 flow-detector input
Measured Flow Quantities Instantaneous, time-averaged and total flow
Display 16 characters × 2 lines, green backlight
Flow Display Range −99.999 to 999.999 (selectable volume/mass rate units)
Total Flow Display Range −99,999.999 to 999,999.999 (selectable volume/mass units)
Pressure Display Range 0.0–1000.0 kPa
Temperature Display Range −20.0 to 80.0°C
Display Refresh 0.1 s or 1.0 s
Meter Flow Accuracy (Excludes Sensor) ±50 ppm of reading ±1 digit
Flow Sensor Pulse Input A/B phase or UP/DOWN; max. 50 kHz
Temperature Sensor Input Pt100, 3-wire, 0.2 mA excitation
Pressure Sensor Input 1–5 V (1 V = 0 kPa)
Analog Outputs 5 BNC outputs; ±10 V, 16-bit D/A
Instantaneous-Flow Analog Update 1 ms
Pressure/Temperature Analog Update 50 ms
Pulse Output 0–5 V via BNC; selectable 1/10/100/1000 pulses per mL
PC Interface USB mini-B
Power Supply DC 9–32 V, 5 W max.
Dimensions W140 × H40 × D100 mm (excluding projections)
Mass Approx. 480 g
Operating Environment 0–40°C; 85% RH max. (noncondensing)

Specified meter accuracy excludes the connected flow detector. Temperature and pressure measurements require compatible sensor configurations. Manufacturer product descriptions reference a pulse for each 0.1 mL; the detailed specification also lists selectable pulse rates of 1/10/100/1000 pulses/mL, so verify pulse setup for the intended integration method.