Home » Electronic Measuring Instruments » Flow & Airflow Measurement » Positive Displacement Flowmeter » OVAL ULTRA OVAL Type S Positive Displacement Flowmeter

OVAL ULTRA OVAL Type S Positive Displacement Flowmeter

OVAL ULTRA OVAL Type S Positive Displacement Flowmeter

Monitor liquid flow and accumulated volume with a positive displacement meter designed for precision measurement, readable indication and practical maintenance diagnostics.

The OVAL ULTRA OVAL Type S measures volumetric throughput with a positive displacement measuring chamber. Its pocketless configuration supports a broad range of compatible liquids including water, gasoline, kerosene, light/heavy fuel oil, paint and selected chemical liquids. Fluid compatibility, seals and wetted materials must be checked for the exact process.

OVAL lists standard, high-temperature and low-temperature variants for smaller nominal sizes, together with additional sizes from 80 to 350 mm. Across the smaller versions, the manufacturer publishes different flow envelopes and temperature limits; these figures do not describe one universal model. Larger meter bodies have additional configuration-specific pressure and material limitations.

The electronic display features a large flow indication and a bar-graph view of instantaneous flow. Glove-operable touch controls and self-diagnostics help operators spot maintenance needs, including estimated meter wear and sensor-lead disconnection.

The manufacturer publishes linearity options of ±0.35% or ±0.15% of reading in its English materials. Electrical supply, analog/pulse outputs, battery operation, communication and explosionproof arrangements are selected by configuration; an external smart-communication unit is required for certain communication functions.

±0.15% Higher linearity option; model-dependent
10–350 mm Nominal size coverage across variants
−60 to +260°C Separate low-/high-temp. small-size variants
IP66 Published enclosure rating; specification-dependent

Precision Displacement Principle

Measures liquid volume using a positive displacement chamber; final accuracy depends on meter size, viscosity and configuration.

Clear Local Indication

Larger instantaneous-flow indication and a bar graph help operators assess running conditions.

Glove-Operable Controls

Touch-style operation supports parameter access during industrial field use, even when wearing gloves.

Predictive Maintenance Alerts

The register estimates meter deterioration and indicates when service attention may be due.

Sensor Diagnostic Functions

Alerts for sensor wiring disconnection improve visibility of abnormal field conditions.

Multiple Process Configurations

Select temperature ratings, power supply, signal output and explosionproof construction to match the application.

Petroleum Product Metering

Measure gasoline, kerosene, diesel and compatible heavy oil at selected pressure, viscosity and temperature conditions.

Chemical Liquid Processing

Monitor appropriate chemical liquids and solvents where wetted-material and seal compatibility is validated.

Paint and Coating Transfer

Track flow and throughput of compatible coating liquids through dispensing or process piping.

Industrial Water Monitoring

Record liquid consumption and monitor water flow in appropriate industrial lines.

High-Temperature Process Lines

Evaluate dedicated high-temperature models for hot liquid transfer rather than assuming standard-model ratings.

Flowmeter Maintenance Programs

Use local status and sensor alerts to schedule inspection and support consistent operational records.

OVAL ULTRA OVAL Type S Positive Displacement Flowmeter Specifications

Measurement principlePositive displacement volumetric measurement
Measuring seriesULTRA OVAL Type S
Nominal size, standard small-range type10–50 mm across manufacturer variants
Nominal size, high/low temperature types20–50 mm
Nominal size, larger bodies80–350 mm; details depend on body construction
Flow envelope, standard small-range0.2 L/h to 44 m³/h across nine types
Flow envelope, high-temperature small-range0.05–44 m³/h across six types
Flow envelope, low-temperature small-range0.03–44 m³/h across six types
Flow envelope, 80–350 mm series4–1,000 m³/h across eight types
Operating temperature, standard small-range−10 to +120°C
Operating temperature, high-temperature small-range+120 to +260°C
Operating temperature, low-temperature small-range−60 to +60°C
Maximum pressure, small-rangeUp to 2.94 MPa; connection-standard dependent
Linearity (English-language product data)±0.35% or ±0.15% of reading; depends on version and calibration
Viscosity basis for published flow envelopes5 to 1,000 mPa·s; model-specific exceptions apply
Body material, listed small-range versionSCS14; large-size materials vary
Flange connections, listed small-range versionJIS 10/16/20/30K; ASME/JPI 150/300
Power arrangementsDC supply or replaceable-battery type
Signal outputsAnalog or pulse on compatible externally powered versions
Explosionproof availabilityExplosionproof and non-explosionproof variants; verify applicable approvals
Ingress protectionIP66 in manufacturer series table
CommunicationParameter setting and monitoring on smart configuration; external communication unit required

Configuration Comparison

VariantStandard, small rangeHigh-temperatureLow-temperature
Nominal size10–50 mm20–50 mm20–50 mm
Series flow envelope0.2 L/h–44 m³/h0.05–44 m³/h0.03–44 m³/h
Operating temperature−10 to +120°C+120 to +260°C−60 to +60°C
Published small-range max. pressureUp to 2.94 MPa*Check order codeCheck order code

Specifications are based on manufacturer-published series information. Actual model capabilities, calibrated accuracy, compatibility, licenses and accessories are configuration-dependent; verify requirements before placing an order.