Four-Channel Ignition and Injection Pulse Signal Conditioning
The ATSENSE PS-100 converts analog current waveforms from a CLP-10 clamp-on AC pickup into 0–5 V pulse signals for engine ignition and fuel-injection timing measurement.
Four input channels accommodate multiple ignition or injector signals. The signal conditioner responds within 3 μs after the input exceeds the selected trigger level and delivers digital high/low pulses through BNC connections.
Trigger levels are selectable at ±0.5 V, ±1 V, ±2 V or ±5 V, while low-pass filter switching helps reduce noise. The settings are provided in paired channel groups (CH1–2 and CH3–4), rather than as four fully independent panel controls.
Combined with the compatible CLP-10 pickup, PS-100 helps identify ignition charging/discharging events and injection-current energizing intervals for analysis using engine data acquisition and timing systems. Input and output grounds are common; the signals are not galvanically isolated.