Clamp-on Detection of Engine Ignition and Injection Timing
The ATSENSE CLP-10 is a compact current-transformer pickup that detects changes in ignition-coil and injector drive currents to provide timing signals for automotive engine testing.
The pickup clamps around an existing harness conductor with a diameter up to 4.5 mm, enabling measurements even on engines that do not have a secondary high-voltage ignition cable. The applicable current range is 0.1–10 A RMS, with 50 A RMS stated as the maximum.
Connect the CLP-10 to an ATSENSE ET-100 engine tachometer for engine-speed measurement or to an ATSENSE PS-100 pulse shaper for evaluating ignition charge, ignition discharge and injection timing. The supplied 5 m coaxial cable terminates in a BNC connector.
Installation direction affects output polarity: in the specified orientation, the output has a positive pulse at spark-plug discharge and when fuel injection stops. Injection-drive current can produce a smaller signal, so instrument triggering must be matched to the waveform.