Home » Manufacturing / Processing / Inspection Equipment » Inspection & Testing Systems » Battery Tester » HIOKI BT3563 Battery HiTESTER (discontinued; BT3563A successor)

HIOKI BT3563 Battery HiTESTER (discontinued; BT3563A successor)

300 V Battery Pack Internal Resistance and Voltage Testing

The HIOKI BT3563 Battery HiTESTER is a benchtop tester for simultaneous internal-resistance (AC-IR) and battery-voltage measurements during cell, module and pack inspection. It supports DC battery voltages up to ±300 V and low-resistance measurements for high-volume production applications.

The original BT3563 uses a 1 kHz AC four-terminal resistance measurement method and provides seven resistance ranges from 3 mΩ to 3 kΩ. A minimum resistance resolution of 0.1 µΩ is available on the 3 mΩ range, while DC voltage measurement offers 6 V, 60 V and 300 V ranges.

Comparator functionality evaluates resistance and voltage independently for production inspection. Standard interfaces include external I/O and RS-232C; the BT3563-01 configuration adds GP-IB and analog resistance output.

300 V Maximum battery measurement voltage
0.1 µΩ Minimum resistance resolution
1 kHz AC four-terminal test frequency
BT3563A Manufacturer-listed successor model

The original BT3563 is listed as discontinued by HIOKI. For a current 300 V production-line model, review the HIOKI BT3563A; for higher-voltage battery packs, compare the HIOKI BT3564 1000 V tester.
Explore additional products from HIOKI.

Simultaneous AC-IR and Voltage

Measure battery internal resistance and open-circuit voltage within the same inspection workflow.

Up to 300 V DC

Evaluate high-voltage modules and packs within the rated ±300 V measurement limit.

Seven Resistance Ranges

Select from 3 mΩ through 3 kΩ to cover low-resistance cells and larger assemblies.

0.1 µΩ Minimum Resolution

Resolve very small resistance changes using the 3 mΩ measurement range.

Production Comparator

Use Hi/IN/Lo judgments for resistance and voltage with combined PASS/FAIL output.

Automation Interfaces

Use RS-232C and external I/O; GP-IB and analog output apply to the BT3563-01 variant.

Battery Pack Production Inspection

Check voltage and AC internal resistance on battery packs rated up to 300 V.

Battery Module Incoming Inspection

Screen assembled modules against application-specific resistance and voltage limits.

EV Battery Assembly Quality Control

Evaluate cells and interconnected assemblies before release or integration.

Battery Tab and Connection Checks

Inspect low-resistance electrical connections using suitable test leads and fixtures.

Fuel Cell Stack Testing

Measure stack voltage and electrical resistance within the instrument rating.

Legacy Test Station Replacement

Identify measurement and interface requirements when upgrading BT3563 installations to BT3563A.

Specification BT3563 / BT3563-01
Product status BT3563 discontinued; BT3563A is the HIOKI-listed upgrade
Measurement method AC four-terminal resistance measurement
Measurement frequency 1 kHz ±0.2 Hz
Maximum input voltage ±300 V DC; ±300 V DC maximum rated voltage to earth
Resistance ranges 3 mΩ / 30 mΩ / 300 mΩ / 3 Ω / 30 Ω / 300 Ω / 3 kΩ
Minimum resistance resolution 0.1 µΩ at 3 mΩ range
Resistance accuracy (standard conditions) ±0.5% reading ±10 digits (3 mΩ); ±0.5% reading ±5 digits (30 mΩ–3 kΩ), with mode-dependent additions
Voltage ranges 6 V / 60 V / 300 V DC
Minimum voltage resolution 10 µV on 6 V range
Voltage basic accuracy ±0.01% reading ±3 digits, with mode-dependent additions
Measurement current 100 mA (3 mΩ range) to 10 µA (3 kΩ range)
Sampling settings EX.FAST / FAST / MEDIUM / SLOW; timing depends on function and mains setting
Comparator Resistance and voltage Hi / IN / Lo; combined PASS / FAIL
Standard interfaces External I/O and RS-232C
Variant-specific interfaces BT3563-01: GP-IB and 0–3.1 V resistance analog output
Power supply 100–240 V AC, 50/60 Hz; 30 VA max.
Dimensions (W × H × D) 215 × 80 × 295 mm
Weight Approx. 2.4 kg

Values describe the legacy BT3563/BT3563-01, not the BT3563A. HIOKI lists the BT3563 as discontinued. Test leads are sold separately; confirm successor and interface requirements before replacing existing production fixtures.