Home » Manufacturing / Processing / Inspection Equipment » Inspection & Testing Systems » Battery Tester » HIOKI BT3562 Battery HiTESTER (60 V, Discontinued)

HIOKI BT3562 Battery HiTESTER (60 V, Discontinued)

60 V Battery Internal Resistance and Voltage Testing for Production Lines

The HIOKI BT3562 Battery HiTESTER is a benchtop battery tester for high-speed 1 kHz AC internal resistance measurement and DC voltage checks on cells, modules and packs up to 60 V.

The BT3562 covers seven resistance ranges from 3 mΩ to 3,000 Ω, with minimum 0.1 µΩ indication, and 6 V / 60 V DC voltage ranges. Simultaneous checks help assess low-resistance battery products at quality-control and production stations.

60 V DC Maximum rated measurement voltage
3 mΩ–3 kΩ Seven internal-resistance ranges
0.1 µΩ Minimum resistance resolution
1 kHz AC internal-resistance test frequency

The tester supports external triggering, independently evaluated resistance and voltage comparator limits, and RS-232C data output for automated inspections. The BT3562-01 configuration adds GPIB and resistance analog output. Measuring leads are sold separately.

HIOKI lists the BT3562 as discontinued and identifies the BT3562A as an upgraded model with up to 100 V measurement and LAN connectivity. Denkei Americas can help review replacements based on electrical range, interfaces and system compatibility.

AC Resistance and DC Voltage Testing

Combines 1 kHz internal-resistance testing with DC voltage measurement for battery QA.

60 V Rated Voltage Measurement

Measures battery cells, modules and smaller packs with ±60 V DC rated input.

Seven Resistance Ranges

Offers 3 mΩ to 3,000 Ω ranges and 0.1 µΩ minimum resolution for low-resistance batteries.

Fast Production-Line Operation

Offers approximately 10 ms measurement response under specified conditions and selectable sampling modes.

Independent Comparator Judgments

Evaluates resistance and voltage against separate limits and provides combined PASS/FAIL output.

Remote Control Interfaces

Includes RS-232C and external I/O; the BT3562-01 version adds GPIB and analog output.

Lithium-Ion Cell Inspection

Measure internal resistance and open-circuit voltage of battery cells during quality checks.

Battery Module Production Testing

Check module resistance and voltage before or after manufacturing stages.

Pack Acceptance Inspection

Apply defined limits to smaller battery packs within the 60 V rating.

Large Low-Resistance Cell Evaluation

Use the 3 mΩ measurement range for suitable large-capacity cells.

Automated Sorting and Comparator Testing

Apply independent resistance and voltage thresholds using external I/O interfaces.

Battery Research and Validation

Track comparative electrical properties across sample builds and aging studies.

SpecificationDetails
ModelBT3562 (discontinued); BT3562-01 variant
Measurement Functions1 kHz AC internal resistance and DC voltage
Maximum Applied Voltage±60 V DC rated input (±70 V DC maximum rated voltage to earth)
Resistance Ranges3 mΩ / 30 mΩ / 300 mΩ / 3 Ω / 30 Ω / 300 Ω / 3 kΩ
Resistance Measurement Span3 mΩ–3,000 Ω nominal ranges; up to 3.1 kΩ indicated
Minimum Resistance Resolution0.1 µΩ (3 mΩ range)
Resistance Basic Accuracy±0.5% rdg. ±10 digits (3 mΩ); ±0.5% rdg. ±5 digits (30 mΩ and higher), slow mode
Test Current Frequency1 kHz ±0.2 Hz
Voltage Ranges6 V DC and 60 V DC
Minimum Voltage Resolution10 µV (6 V range)
Voltage Accuracy±0.01% rdg. ±3 digits, specified slow mode
Sampling ModesEX.FAST 4 ms / FAST 12 ms / MEDIUM 35 ms / SLOW 150 ms (typical)
Measurement ResponseApprox. 10 ms under specified conditions
ComparatorIndependent resistance/voltage Hi/IN/Lo; combined PASS/FAIL
InterfacesRS-232C, external I/O; GPIB on BT3562-01
Analog OutputResistance analog output on BT3562-01 only
Power Supply100–240 V AC, 50/60 Hz, 30 VA maximum
Dimensions215 W × 80 H × 295 D mm
MassApprox. 2.4 kg
Test LeadsOptional; not included
Current Replacement CandidateBT3562A; up to 100 V and LAN interface (verify application fit)

BT3562 is discontinued. The BT3562A is an upgraded successor candidate, not necessarily a drop-in replacement; check interfaces, measurement ranges and fixture compatibility. Leads must be purchased separately.