12-Channel Battery Cell Simulation for BMS Validation
The HIOKI SS7081-50 generates and measures simulated battery cell voltages across 12 independent channels to validate battery management systems without using live battery cell strings.
Each channel combines programmable DC voltage output with source/sink current and measurement capability. This enables BMS engineers to reproduce cell voltage conditions, current balance behavior and abnormal states such as cell shorts or open-wire conditions.
Voltages are programmable independently from 0 to 5.0250 V, and instrument series connections can be configured for high-voltage BMS tests up to a maximum combined output of 1,000 V. Low-current measurements use a dedicated 100 µA range for BMS standby current and leakage evaluation.
LAN control supports automated test setups and software-driven sequences. HIOKI specifies that the control PC, control software and BMS wiring are not included with the instrument; clarify the required software download, cables and test-system design before procurement.