Home » Electronic Measuring Instruments » Data Loggers & Data Acquisition » Data Logger » HIOKI PW3365 Clamp On Power Logger

HIOKI PW3365 Clamp On Power Logger

Non-Metal-Contact Voltage Measurement for Energy Logging

The HIOKI PW3365 combines clamp-on current measurement with covered, non-metal-contact voltage sensing to simplify power logging at facilities and equipment panels.

Unlike conventional voltage test leads that contact live conductive terminals, the PW3365 uses the PW9020 safety voltage sensor to measure from outside supported insulated wiring. This design helps reduce short-circuit exposure during eligible power measurement tasks.

90–520 V Effective AC voltage measurement range
3-Phase, 4-Wire Supports common facility wiring configurations
13th Order Harmonic measurement on 50/60 Hz power lines
PW9020 Non-metal-contact safety voltage sensor

The PW3365 supports single-phase and three-phase systems, energy logging, power demand measurements and analysis of harmonics to the 13th order. Measurements can be logged to SD/SDHC media or internal memory.

Current and power measurements require compatible clamp-on current sensors, sold separately. The non-contact voltage sensing capability does not remove the need to follow electrical safety procedures, observe voltage ratings and assess conductor compatibility.

Non-Metal-Contact Voltage Sensor

PW9020 senses voltage through supported insulated cables without exposed metallic contact to live conductors.

Three-Phase Energy Logging

Records power, energy and demand on supported single- and three-phase power circuits.

Harmonic Analysis to 13th Order

Evaluates harmonics in voltage and current signals on 50/60 Hz electrical systems.

QUICK SET Connection Support

Guided setup assists with selecting wiring configurations and checking connections.

Long-Term Recording

Supports SD/SDHC memory card or internal-memory logging with configurable intervals.

Field-Ready Operation

Compact body, optional battery operation and LAN/USB connectivity support onsite surveys.

Safer Facility Energy Audits

Measure power on compatible insulated conductors without exposing live terminals for the voltage sensing connection.

Electrical Panel Load Studies

Record demand patterns and energy use on distribution and branch circuits.

Production Equipment Monitoring

Compare the consumption of equipment during different operating cycles.

Harmonic Trend Review

Examine harmonics up to the 13th order on 50/60 Hz circuits.

Energy Conservation Verification

Document electricity-use changes after system upgrades or operational adjustments.

Maintenance and Troubleshooting

Review power, current and voltage trends while investigating facility electrical conditions.

SpecificationPW3365
Order code PW3365-20 (English model)
Measurement lines 1-phase 2-wire (up to 3 circuits); 1-phase 3-wire; 3-phase 3-wire; 3-phase 4-wire
Nominal voltage range 400 V AC
Effective voltage measurement 90–520 V AC
Voltage sensing PW9020 non-metal-contact safety voltage sensor
AC current ranges 500 mA to 5 kA, dependent on current sensor
Leakage current range 50 mA to 5 A with compatible leakage clamp sensor
Power ranges 200 W to 6 MW, wiring/sensor dependent
Harmonics Up to 13th order
Voltage accuracy ±1.5% rdg. ±0.2% f.s. (PW3365-20 with PW9020)
Current accuracy ±0.3% rdg. ±0.1% f.s. plus clamp-sensor accuracy
Active power accuracy ±2.0% rdg. ±0.3% f.s. plus sensor accuracy (PF = 1)
Data-save interval 1–30 seconds; 1–60 minutes (14 selections)
Data storage SD/SDHC card or internal memory
Interfaces LAN and USB
Dimensions, main unit 180 W × 100 H × 48 D mm (without PW9002)

PW9020 safety voltage sensors are included in the standard PW3365 configuration; current clamps are sold separately. Confirm compatible insulated conductor, measurement category and installation procedures.