HIOKI MR8880 Memory HiCorder

HIOKI MR8880 Memory HiCorder

Four isolated analog channels for maintenance, three-phase power and transient fault recording.

The HIOKI MR8880 Memory HiCorder records voltage waveforms and logic events simultaneously for field diagnostics and equipment troubleshooting. Four mutually isolated analog inputs, eight logic inputs and trigger functions make the instrument suitable for three-phase power systems and industrial controls.

The recorder provides a high-speed waveform mode and a real-time recording mode. It samples at up to 1 MS/s across all channels in high-speed mode, with DC to 100 kHz analog bandwidth and rated terminal-to-earth insulation of CAT III 600 V or CAT IV 300 V.

A thermal printer can be added using the separately purchased MR9000 Printer Unit. The legacy imported specifications contained an unrelated "XER-W85" value in the printing row; that entry is not an MR8880 printer model and must be removed.

4 + 8 channels Isolated analog + logic
1 MS/s Simultaneous high-speed sampling
CAT III 600 V Terminal-to-earth category
MR9000 Optional printer unit

Four Isolated Analog Channels

Capture multiple voltage waveforms in parallel with separation between analog channels and frame.

Eight Logic Inputs

Use digital signals to analyze controller timing, relays and other switching logic.

High-Speed or Long-Term Recording

Switch between high-speed memory acquisition and real-time recording for longer investigations.

Direct High-Voltage Measurement

Rated 600 V AC/DC between terminals and CAT III 600 V terminal-to-earth per manufacturer specifications.

Field-Oriented Construction

Protective side panels, portable operation and −10°C to 50°C operating conditions support demanding sites.

Optional Thermal Printer

MR9000 printer unit provides on-site hard copy; it is not a standard integrated printer.

Three-Phase Electrical Systems

Capture three phase voltage waveforms and a fourth reference or control trace.

Circuit Breaker and Relay Testing

Correlate logic inputs and voltage transitions to assess switching timing.

Power Interruption Investigation

Trigger on sudden voltage changes or dips and review pre-event and post-event waveforms.

Industrial Machinery Maintenance

Record intermittent faults and electrical signals at manufacturing or utility sites.

Power Supply Troubleshooting

Examine abnormal start-up transients and power disturbances.

Field Service Documentation

Save waveforms to removable media or print results on location using the optional printer.

HIOKI MR8880 Memory HiCorder Specifications

Input channels 4 isolated analog channels + 8 logic channels
Maximum sampling 1 MS/s (1 μs interval) simultaneous, high-speed function
Analog bandwidth DC to 100 kHz (±3 dB)
Voltage sensitivity 10 mV to 100 V/div, 13 ranges; 10 div full scale
Maximum voltage between terminals 600 V AC/DC
Maximum terminal-to-earth rating 600 V AC/DC CAT III; 300 V AC/DC CAT IV
RMS mode 30 Hz to 10 kHz, crest factor 2
Real-time recording interval 100 μs to 1 minute, 19 selections
Memory capacity 14-bit × 1 Mword/channel
Removable storage CF Type I card (up to 2 GB) and USB memory
Display 5.7-inch VGA TFT color LCD, 640 × 480
Connection to PC USB 2.0 mini-B, file transfer and external PC control
Printer option MR9000, 112 mm-wide thermal roll; 10 mm/s recording speed
Operating temperature −10°C to 50°C (manufacturer operating condition)
Power AC adapter Z1002; optional battery pack Z1000, AA batteries or 10–28 V DC input
Dimensions / mass 205 W × 199 H × 67 D mm; approx. 1.66 kg with Z1000 battery
Order code MR8880-20 (English model); printer and test leads sold separately

The printer option is MR9000, not "XER-W85" (an unrelated equipment model introduced by a corrupted legacy table). Printing is unavailable on AA alkaline batteries. Use properly rated test leads.