Home » Electronic Measuring Instruments » Data Loggers & Data Acquisition » Data Logger » HIOKI LR8515 Wireless Voltage/Temp Logger

HIOKI LR8515 Wireless Voltage/Temp Logger

Two-Channel Bluetooth Logging of Voltage and Thermocouple Temperature

The HIOKI LR8515 records DC voltage or temperature from K- and T-type thermocouples on two individually configurable, isolated input channels for wireless field and laboratory data collection.

Choose voltage ranges from ±50 mV to ±50 V or thermocouple measurements from −200°C to 999.9°C as supported by the selected sensor type. A minimum 0.1-second recording interval helps capture changing test conditions without permanent communication wiring.

2 Isolated Inputs Configure voltage or K/T temperature per channel
±50 V DC Maximum specified voltage input
0.1 s Minimum Fastest configurable logging interval
500,000 Points/Ch Internal recording memory per channel

Bluetooth wireless communication supports data retrieval from compatible Windows PCs/tablets or Android devices. The LR8515 can also function as a measurement module with compatible LR8410 wireless logging stations for real-time monitoring.

Two AA batteries, an optional Z2003 AC adapter and compatible external DC supply provide flexible powering. Approximate AA battery operation is seven days with Bluetooth enabled and a one-second recording interval. Thermocouples and other connecting accessories must be selected separately.

Independently Configurable Channels

Assign either DC voltage or K/T thermocouple measurement to each of the two isolated inputs.

Fast Measurement Logging

Select recording intervals down to 0.1 second for varying voltage and temperature signals.

Four DC Voltage Ranges

Choose ±50 mV, ±500 mV, ±5 V or ±50 V measurement ranges for different sensor outputs.

Bluetooth Download and Review

Download data on compatible Windows PCs or Android smart devices using HIOKI collection software.

High-Capacity Local Storage

Record up to 500,000 measurement points per channel with no constant host connection.

Portable, Low-Wiring Setup

Small enclosure and AA, adapter or external DC power support field test setups and temporary validation.

Voltage and Temperature Correlation

Record changing DC voltage and thermocouple temperature during the same product test.

Photovoltaic System Maintenance

Trend panel voltage or sensor outputs while measuring associated temperatures.

Automotive Electronics Validation

Observe voltage and temperature changes during component or vehicle subsystem checks.

Heat Flow Sensor Monitoring

Record a compatible sensor voltage alongside a temperature measurement.

Equipment Thermal Troubleshooting

Monitor changing surface or equipment temperatures using properly selected K/T thermocouples.

Development and Field Testing

Collect synchronized trends from two independent measurement points without fixed data cabling.

Specification Details
Input Channels 2 isolated channels, selectable DC voltage or K/T thermocouple per channel
Terminal Type M3 screw terminal block
DC Voltage Ranges ±50 mV / ±500 mV / ±5 V / ±50 V
Maximum Input Voltage ±50 V DC; maximum inter-channel voltage 60 V DC
Voltage Resolution 0.01 mV on ±50 mV range; 0.1 mV / 1 mV / 10 mV on higher ranges
Basic Voltage Accuracy ±0.05 mV on ±50 mV full-scale range
Thermocouple Types K and T; maximum indicated resolution 0.1°C
Thermocouple Measurement Range K: −200°C to 999.9°C; T: −200°C to 400°C (type-specific range)
K Thermocouple Accuracy ±0.8°C from −100°C to 999.9°C; additional reference-junction error when internally compensated
Recording Interval 0.1–30 seconds or 1–60 minutes; 16 selections
Memory Capacity 500,000 data points per channel
Wireless Communication Bluetooth; approximately 30 m line of sight depending on environment
Data Retrieval Dedicated HIOKI collection software for supported Windows/Android devices
Power Sources 2 × AA alkaline batteries; optional Z2003 AC adapter; external 5–13.5 V DC
Battery Life, Bluetooth ON Approx. 7 days at 1-second interval (23°C)
Battery Life, Bluetooth OFF Approx. 2.5 months at 1-minute interval (23°C)
Dimensions 85 W × 75 H × 38 D mm
Mass Approx. 126 g without batteries

Thermocouple accuracy varies by sensor type and temperature region, and reference-junction compensation accuracy must be added where applicable. The original WooCommerce row “Model XER-W85” belongs to a different manufacturer and must be deleted from this product.