SMU capable of testing high-voltage devices Output voltage up to +250 V and output current up to ±320 Ma
The 6247C/6247G is a DC voltage current source/monitor designed for evaluating high voltage semiconductors and LED luminaires that demand high efficiency and low power consumption, capable of outputting voltage up to +250 V and current up to ±320 mA. It provides high accuracy of ±0.025 % with 4½-digit source resolution and 5½-digit measurement resolution. The 6247C/6247G features the well-established VSIM, ISVM, sweep and pulse generation functions. Also, leak current measurement up to 10 pA is possible. In addition, it is equipped with the various types of sweep functions such as linear, fixed, random and two slope linear sweep functions, the pulse measurement function with the minimum pulse width of 50 μs, the micro voltage and current measurement function with the minimum resolution of 10 μV or 10 pA, and the suspend function that controls the optimized output status. By using these functions, the 6247C/6247G can be widely used for evaluating or testing semiconductor and other electronic components in R&D fields and production lines.- Wide ranging source and measurement Voltage: -15 V to +250 V Current: 0 to ±320 mA
- Source resolution of 100 μV/100 pA
- 5½-digit display (±320999) with measurement resolution of 10 μV/10 pA
- Basic source and measurement accuracy of ±0.02%
- Pulse measurement with minimum pulse width of 50 μs and resolution of 1 μs
- Sink-enabled bipolar output
- GPIB (6247G), RS232 (6247C) and USB (6247G/6247C)



There are four source modes: DC, pulse, DC sweep, pulse sweep. Then, the sweep modes are classified into four sweep types: fixed sweep, linear sweep, random sweep (any type of waveform generation by user's programming), two slope linear sweep (linear sweep with step value switching). The minimum pulse width is 50 µs. The minimum cycle is 2 ms, or 500 µs without measurement.

In voltage or current source, the HI/LO limiter settings are very important. The 6247C/6247G has a function that can set the HI and LO limiters individually. Furthermore, for the voltage-limiter, both HI and LO limiters can be set homo-polar.
This prevents a capacitor or a battery from being over-discharged. Also, it is suitable for evaluating devices such as LDs that are used at a constant current and do not tolerate reverse voltage application.



| Model | 6247C | 6247G | |
| Number of digits for generation | 4½ | ||
| Output method | Bipolar | ||
| Maximum output (top) | Voltage | +250 V, -15 V/320 mA | |
| 100 μV | |||
| Minimum resolution (bottom) | Current | ±320 mA/+250 V, -15 V | |
| 100 pA | |||
| Number of digits for measurement | 5½ | ||
| Accuracy (typical range) | 0.02 % | ||
| Minimum measurement resolution | Voltage | 10 μV | |
| Current | 10 pA | ||
| Maximum measurement resistnace / Minimum resolution | 125 GΩ/30 μΩ | ||
| Pulse application / Measurement | Available | ||
| Minimum pulse width | 50 μs | ||
| Interface | USB, RS232 | USB, GPIB | |