Home » Electronic Measuring Instruments » Power Supplies & Electronic Loads » Source Measure Unit » ADCMT 6247C/6247G DC Voltage Current Source/Monitor

ADCMT 6247C/6247G DC Voltage Current Source/Monitor

ADCMT
Supplier / Manufacturer: ADCMT
Model: 6247C / 6247G

Contact Us

High-Voltage SMU for Semiconductor and LED Device Evaluation

The ADCMT 6247C and 6247G are precision source measure units designed for high-voltage semiconductor, LED, and electronic-device characterization, providing voltage output up to +250 V and current output up to ±320 mA.

Both models combine 4½-digit source control with 5½-digit measurement, ±0.02% basic accuracy, bipolar source and sink operation, and minimum measurement resolution of 10 μV and 10 pA.

+250 V High-voltage source capability
±320 mA Bipolar current source and sink operation
10 pA Minimum current measurement resolution
50 μs Minimum pulse source and measurement width

Voltage sourcing covers −15 V to +250 V while current sourcing supports ±320 mA. This asymmetric voltage range is particularly suited to devices requiring high positive bias together with reverse or leakage-current characterization.

Linear, fixed, random, and two-slope linear sweeps, pulse measurement, resistance measurement, and selectable suspend modes provide flexible characterization for R&D and production testing. The 6247C provides USB and RS-232 interfaces, while the 6247G provides USB and GPIB.

High-Voltage Output to +250 V

Source voltage from −15 V to +250 V for high-voltage semiconductor, LED, and electronic-device characterization.

±320 mA Source and Sink

Bipolar current sourcing and sinking up to ±320 mA supports active device testing across positive and negative operating regions.

10 pA Current Measurement

Measure leakage and low-level device current with minimum resolution down to 10 pA.

50 μs Pulse Measurement

Generate and measure pulses with a minimum width of 50 μs and 1 μs programming resolution.

Flexible Sweep Functions

Linear, fixed, random, and two-slope linear sweep modes support automated I-V and device-characteristic evaluation.

Resistance Measurement

Measure resistance up to 125 GΩ with minimum resistance resolution down to 30 μΩ.

Selectable Suspend Modes

Optimized output suspend states help reduce unnecessary relay operation and support faster automated measurement sequences.

Choice of System Interfaces

The 6247C provides USB and RS-232 connectivity, while the 6247G provides USB and GPIB for automated test-system integration.

High-voltage semiconductor characterization
LED and LED module evaluation
Semiconductor leakage-current measurement
Diode I-V characterization
High-voltage electronic component testing
Pulse-based semiconductor evaluation
Production-line device testing
Research and development characterization
Specification 6247C 6247G
Source Resolution 4½ digits 4½ digits
Output Method Bipolar Bipolar
Voltage Output Range −15 V to +250 V −15 V to +250 V
Maximum Current ±320 mA ±320 mA
Minimum Voltage Source Resolution 100 μV 100 μV
Minimum Current Source Resolution 100 pA 100 pA
Measurement Resolution 5½ digits 5½ digits
Basic Accuracy ±0.02% ±0.02%
Minimum Voltage Measurement Resolution 10 μV 10 μV
Minimum Current Measurement Resolution 10 pA 10 pA
Resistance Measurement Up to 125 GΩ / 30 μΩ minimum resolution Up to 125 GΩ / 30 μΩ minimum resolution
Minimum Pulse Width 50 μs 50 μs
Interface USB, RS-232 USB, GPIB