HIOKI SW2001 High Voltage Multiplexer
Consolidate multiple winding-test instruments with protected high-voltage and four-terminal switching for production lines.
The HIOKI SW2001 High Voltage Multiplexer reduces repeated cable reconnections when evaluating motor windings across multiple electrical test methods. One switching platform can connect insulation and withstand-voltage instruments, an impulse winding tester, an LCR meter and a four-terminal resistance meter to selected motor test points.
The system supports six typical inspection methods: winding resistance, inductance, insulation resistance, hipot, impulse/surge and partial-discharge testing. It does not generate test voltage or measure those parameters on its own; external instruments and correctly specified fixtures perform the measurement.
A protective discharge function helps dissipate residual energy stored in a winding before switching to sensitive low-voltage equipment. The manufacturer specifies 5 kV AC rms / 5 kV DC hipot switching, 8 kV peak impulse switching and up to 100 A peak permissible impulse current under rated conditions.
Current regional product listings explicitly show SW2001-04, -08 and -16 variants. Hioki launch materials and other documentation also describe an SW2001-24 configuration for up to 24 output channels; confirm local procurement before quoting. For AC or surge PD system builds, ST9200A and ST9201-50 are optional factory-installed PD sensors that must be selected when the multiplexer is ordered.