HIOKI SW2001 High Voltage Multiplexer

HIOKI SW2001 High Voltage Multiplexer

Consolidate multiple winding-test instruments with protected high-voltage and four-terminal switching for production lines.

The HIOKI SW2001 High Voltage Multiplexer reduces repeated cable reconnections when evaluating motor windings across multiple electrical test methods. One switching platform can connect insulation and withstand-voltage instruments, an impulse winding tester, an LCR meter and a four-terminal resistance meter to selected motor test points.

The system supports six typical inspection methods: winding resistance, inductance, insulation resistance, hipot, impulse/surge and partial-discharge testing. It does not generate test voltage or measure those parameters on its own; external instruments and correctly specified fixtures perform the measurement.

A protective discharge function helps dissipate residual energy stored in a winding before switching to sensitive low-voltage equipment. The manufacturer specifies 5 kV AC rms / 5 kV DC hipot switching, 8 kV peak impulse switching and up to 100 A peak permissible impulse current under rated conditions.

Current regional product listings explicitly show SW2001-04, -08 and -16 variants. Hioki launch materials and other documentation also describe an SW2001-24 configuration for up to 24 output channels; confirm local procurement before quoting. For AC or surge PD system builds, ST9200A and ST9201-50 are optional factory-installed PD sensors that must be selected when the multiplexer is ordered.

4 / 8 / 16 chRegional listed variants
24 chDocumented; availability check
8 kV peakImpulse switching rating
6 testsOne multi-instrument system

Multiple Electrical Tests, One Fixture

Switch among winding resistance, LCR/inductance, insulation, hipot, impulse and partial-discharge test connections.

High-Voltage and Four-Terminal Inputs

Dedicated 2-terminal high-voltage and 4-terminal low-voltage interfaces protect workflow integrity.

Protected Discharge Switching

Discharge accumulated energy from tested windings before relays connect sensitive low-voltage equipment.

Selectable Output-Channel Capacity

Choose SW2001-04, -08 or -16 from regional listings; ask about the documented -24 configuration where needed.

Factory PD Sensor Integration

Specify ST9200A for AC PD and/or ST9201-50 for impulse PD when ordering an integrated ST4200-50 system.

Automation and Industrial Connectivity

Control switching and monitor status through LAN, USB and EXT. I/O with interlock, channel delay and stored settings.

Stator Production Inspection

Reduce manual rewiring between insulation, hipot, inductance and winding-resistance stations.

EV Motor End-of-Line Testing

Coordinate multi-point electrical tests for motor windings with external instruments and fixtures.

Integrated AC and Surge PD Systems

Pair with ST4200-50 and appropriately ordered PD sensors to route dedicated partial-discharge measurements.

High-Voltage Surge Test Routing

Switch ST4030A test connections in an installation designed for rated impulse voltages and currents.

Multi-Motor Production Fixtures

Evaluate complex multi-motor test architectures; three-motor workflows depend on model/channel configuration.

Automated Fixture Development

Build repeatable PLC/PC-driven switching programs with external control I/O and protective discharge logic.

HIOKI SW2001 High Voltage Multiplexer Specifications

Specifications refer to published model documentation and specific configurations. Confirm selected options, safety ratings and software revisions before ordering.

SpecificationDetails
Equipment functionSwitching multiplexer; requires external measurement instruments
High-voltage input interfaces2 channels: HIPOT and IMPULSE, 2-terminal
Low-voltage input interfaces2 channels: LCR and RESISTANCE, 4-terminal
Regional listed variantsSW2001-04 (4 ch), SW2001-08 (8 ch), SW2001-16 (16 ch)
Documented extended variantSW2001-24 (24 ch): in launch/manual documentation; verify local availability
Output connectionsSOURCE and SENSE per output channel
Rated hipot routing5 kV AC rms / 5 kV DC / 7.07 kV peak
Rated impulse routing8 kV peak (impulse)
Low-voltage input limit30 V AC rms / 60 V DC / 42.4 V peak
Maximum allowable impulse current100 A peak
Relay life5 million or more cycles as a reference value; not guaranteed
Partial-discharge optionsFactory-fitted ST9200A (AC PD) and ST9201-50 (impulse PD); not standard
Available functionsSwitching, interlock, channel delay, protection/accelerated discharge, setting backup
InterfacesLAN, USB and EXT. I/O
AC input100–240 V AC, 50/60 Hz; max. 120 VA
SizeApprox. 439.2 W × 265.9 H × 770 D mm
SW2001-04 massApproximately 20.5 kg, excluding factory PD sensor options
SW2001-08 massApproximately 22.5 kg, excluding factory PD sensor options
SW2001-16 massApproximately 27.0 kg, excluding factory PD sensor options
SW2001-24 massApproximately 31.5 kg per published documentation; order availability varies
Current PD sensor module massST9200A adds approx. 1.38 kg; ST9201-50 adds approx. 0.32 kg (regional spec)
Operating temperature0°C to 40°C in published manual
Included itemsPower cord, startup guide, operating precautions, support feet, EXT. I/O connectors