Bench-type optical power meter suitable for R&D and production of optical disks
The 8250A is a bench-type optical power meter, which is most suitable for R&D and production of LDs, optical pickups, and drives for optical disks. It has 0.001 dB resolution and 5½-digit display and is also equipped with GPIB and USB interfaces as standard, allowing easy automated system establishment. Nine kinds of optical sensors with various purpose (general-purpose, blue-violet, high-power, three-wavelength) and different shapes (thin-type, cylindrical-type) are available. The three-wavelength optical sensors 82314B, 82324B and 82314BW are capable of measuring 405 nm, 650 nm, 780 nm wavelength ranges. The blue-violet optical sensors 82312B and 82322B have realized a flat wavelength sensitivity characteristic and low dependency on an angle of incidence in the 405 nm range. The high-power optical sensors 82313B and 82323B enable high-power measurement of up to 200 mW. Furthermore, the optical sensors for the TQ8210/TQ8215 series are also usable.- 5 ½-digit display
- A desk-top type; equipped with GPIB and USB
- Wide lineup of sensors are available for each application
High-resolution measurement and large-sized display
By adopting low-noise design and a high-resolution A/D converter, the 8250A achieves measurement with a high resolution of 0.001 dB that never overlooks subtle change.
Nine types of optical sensors to meet various applications ● Blue-violet sensors to measure lasers of Blu-ray Disc
To measure blue-violet lasers precisely, the 82312B and 82322B blue-violet sensors have realized a maximally flat wavelength sensitivity characteristic. This saves time in performing sensitivity correction at each measurement and always offers high-accuracy measurement results.
By adopting low-noise design and a high-resolution A/D converter, the 8250A achieves measurement with a high resolution of 0.001 dB that never overlooks subtle change.Nine types of optical sensors to meet various applications ● Blue-violet sensors to measure lasers of Blu-ray Disc
82312B
82322B
● Three-wavelength sensors to measure lasers with different wavelengths
82314B
82314BW
82324B
● High-power sensors to measure high-power lasers for write
82313B
82323B
● Low-priced and easy-to-use general-purpose sensors
The 82311B and the 82321B are low-price general-purpose sensors that can be used in a wide wavelength range from 390nm to 1100nm. The calibration wavelength is 780nm and the correction value is stored in the sensors. Sensitivity correction of other wavelengths is also available by using the options.
82311B
82321B

| Display resolution | 0.1 pW (display in W), 0.001 dB (display in dBm) | ||
| Accuracy (To be added to eash sensor accuracy) Conditoion: within 24 hours after offset zero execution, unit: W, 5½-digit display, CF=1 | 20 nW range | ±(0.55 %+2000 digits) | |
| 200 nW range | ±(0.15 %+200 digits) | ||
| 2 μW to 200 mW range | ±(0 %+70 digits) | ||
| Diplay | VFD Wavelength display: 4 digits Power display: 5½ digits (Uni: mW, μW, nW, dBm or dBr) | ||
| Range switching | Auto, manual or remote switching among 8 ranges | ||
| Measurement speed | FAST: 10 readings/s, MED: 5 readings/s, SLOW: 2 readings/s FAST: 10 readings/s only for remote control via USB or GPIB and and hold or trigger measurement | ||
| Wavelength sensitivity correction | Automatic correction of sensor wavelength sensitivity by wavelength setting (in 1nm step) | ||
| Interface | Analog output, USB, GPIB | ||