Home » Optical / Imaging / Precision Devices » Dimensional & Surface Metrology » Thickness Meter » ONO SOKKI CL-7100 Series Non-Contact Thickness Meter

ONO SOKKI CL-7100 Series Non-Contact Thickness Meter

ONO SOKKI CL-7100 Series Non-Contact Thickness Meter

Non-contact thickness and gap measurement for metal sheets, silicon wafers, and EV battery films.

The ONO SOKKI CL-7100 Series measures material thickness without contacting the workpiece. With a suitable pair of displacement sensors, the system derives thickness from sensor-to-target gaps, helping reduce deformation and surface damage during inspection.

For conductive and semiconductor materials, supported measurement items include thickness, Gap A, Gap B, and A–B height difference or parallelism. Insulator thickness measurement requires the optional CL-0740 function and a suitable sensor/reference arrangement.

The system combines a 4.3-inch touch display and a 10 ms update cycle with configurable functions. High-resolution measurement, Pt100 temperature measurement, comparator outputs, and Ethernet communications require the appropriate optional modules.

Non-contactWorkpiece thickness and dual-sensor gap inspection
0.02 µmBest listed resolution with selected sensor and optional configuration
10 msMeasurement update cycle
4.3-inchTouchscreen showing up to four measurement items

Non-contact thickness inspection

Inspect sensitive sheet, wafer, and film surfaces without physical probe pressure.

Dual-sensor gap measurement

Combine two displacement sensors to calculate thickness from the established sensor spacing.

High-resolution configurations

Achieve as fine as 0.02 µm resolution with eligible sensors and optional CL-0720/CL-0722 modules.

Parallelism and height difference

Measure A–B differences for supported conductive or semiconductor targets.

Temperature measurement and compensation

Add CL-0741 and a compatible Pt100 sensor where temperature tracking is needed.

Production system integration

Use standard RS-232C; optional CL-0751 Ethernet and comparator functions support system expansion.

Silicon Wafer Thickness

Measure delicate wafer substrates without making physical contact.

EV Battery Film Inspection

Inspect thin battery-related films and conductive sheets during process development.

Electrical Steel Sheets

Evaluate sheet thickness and variation in manufacturing and R&D.

Metal Sheet Quality Control

Monitor aluminum and other conductive materials for thickness consistency.

Parallelism and Gap Analysis

Assess opposed surfaces and A–B gap differences in precision assemblies.

Plastic and Insulator Testing

Measure compatible homogeneous insulating materials with the optional CL-0740 function.

SpecificationDetails
Measurement principleDual displacement sensors for conductive/semiconductor thickness; optional insulator method
Measured itemsThickness, Gap A, Gap B, A–B height difference/parallelism; temperature with optional CL-0741
Standard resolution0.1 µm (VE-2011/VE-5010/VE-5011/VE-1020/VE-1021); 0.5 µm (VE-1520); 1.0 µm (VE-3020/VE-8020/VE-8021)
High-resolution optionCL-0720: 0.02 µm with VE-2011; 0.05 µm with VE-5010/5011 (0.02 µm with CL-0722); sensor-dependent otherwise
Standard accuracy±0.15% full scale with listed standard sensors
High-resolution accuracy±0.12%, ±0.10%, or ±0.05% full scale, depending on sensor and option
Measurement update cycle10 ms
Display4.3-inch touch-panel LCD, up to four items
CommunicationsRS-232C standard; Ethernet optional via CL-0751
Other optional functionsCL-0740 insulator measurement; CL-0741 Pt100 temperature; CL-0731/0732 comparator
Power supply100–240 VAC ±10%, 50/60 Hz; ≤36 VA
Dimensions / mass210 × 99 × 150 mm (W × H × D); approximately 1.6 kg
Warm-upAt least 40 minutes

Specifications and available options depend on the exact model and configuration. Consult ONO SOKKI documentation and Denkei Americas for selection and quotations.