Home » Electronic Measuring Instruments » Sensors, Probes & Accessories » Strain Gauge » KYOWA KFGS General-purpose Foil Strain Gages

KYOWA KFGS General-purpose Foil Strain Gages

Flexible General-Purpose Foil Strain Gages for Stress Analysis

KYOWA KFGS general-purpose foil strain gages use a flexible polyimide base and CuNi alloy sensing element for precision strain measurement in engineering laboratories and field tests.

The KFGS family offers multiple gage lengths, grid patterns and resistance values including uniaxial, biaxial and triaxial rosette designs. The approximately 14 µm base supports conformity to a range of measured surfaces.

≈14 µmPolyimide base thickness
−196°CLower operating limit with qualifying installation materials
+150°CUpper operating limit with qualifying installation materials
10–100°CSelf-temperature-compensation operating span

Its moisture-resistant design can serve indoor and outdoor work, but suitability for wet or harsh environments depends on surface preparation, adhesive, cable and protective coating. For direct water exposure, do not infer that the installation is waterproof without suitable protection.

Operating temperature and self-temperature compensation are different specifications. Depending on approved adhesive and lead-wire combinations, the stated operating limits can reach −196°C to +150°C; self-temperature-compensation behavior is specified within the narrower 10°C to 100°C range.

Flexible Polyimide Backing

A thin base adapts to strain measurement on a variety of supported surfaces.

CuNi Foil Sensing Grid

Copper-nickel alloy foil provides the resistive sensing element.

Wide Pattern Selection

Choose uniaxial, biaxial, triaxial and other grid configurations.

Moisture-Resistant Construction

Engineered for many indoor and field measurements when installed and protected appropriately.

Material-Matched Compensation

Select compensation variants according to the expansion coefficient of the material being tested.

Adhesive and Lead-Wire Options

Configure each installation for its actual temperature and environmental exposure.

Structural Stress Analysis

Monitor local strain on metal and other compatible structural components.

Automotive Component Testing

Measure deformation in mechanical assemblies during development and durability trials.

Material Property Evaluation

Capture strain responses during controlled load and temperature studies.

Mechanical Design Verification

Validate stress distribution against design and simulation results.

Field Strain Monitoring

Instrument appropriate structures outside the laboratory with proper weather protection.

Multiaxial Strain Measurement

Use rosette-pattern variants to study principal strain directions and stress states.

SpecificationDetails
SeriesKFGS General-purpose Foil Strain Gages
Sensing materialCuNi alloy foil
Base materialPolyimide resin
Base thicknessApproximately 14 µm
Gage patternsUniaxial, biaxial, triaxial and other catalog variants
Catalog resistance examples60 Ω, 120 Ω, 350 Ω, 500 Ω, 1000 Ω; depends on SKU
Operating temperature with CC-33A−196 to +120°C
Operating temperature with CC-35−30 to +120°C (current manufacturer specification; older Denkei copy says −10°C)
Operating temperature with CC-36−30 to +100°C
Operating temperature with EP-340−55 to +150°C
Operating temperature with PC-600−196 to +150°C
Typical lead wire: polyester-coated copper−196 to +150°C
Typical lead wire: vinyl-coated L-6/L-7−10 to +80°C
Typical lead wire: L-11/L-12−100 to +150°C
Self-temperature-compensation span10 to 100°C
Thermal expansion matching values5, 11, 16, 23, 27 × 10⁻⁶ /°C
Approximate room-temperature strain limit5% (catalog reference value)
Typical fatigue life1.2 × 10⁷ cycles at ±1,500 µm/m (catalog condition)

Operating temperature is determined by the complete gage, adhesive, lead-wire and protective-coating combination. The self-temperature-compensation span is not the full ambient operating limit. KFGS is a family, not one fixed resistance or grid geometry.