Keisoku Giken RM-104 Digital Ripple & Noise Meter

RM-104 Digital Ripple & Noise Meter

Repeatable DC power-supply ripple and noise measurements for production inspection, maintenance and automated quality checks.

The Keisoku Giken RM-104 digitally measures the DC output voltage and peak-to-peak ripple/noise generated by switching power supplies. It is intended for tasks where interpreting a wideband oscilloscope trace can yield inconsistent readings among operators, especially when a clean quantitative value and repeatable pass/fail judgment are needed.

Users can separate broadband ripple/noise, ripple voltage, high-frequency noise, switching ripple and AC ripple with the RM-104 filter/mode selections. The published THRU measurement path spans 50 Hz to 100 MHz, while the selectable low-pass, high-pass and 20 MHz bandwidth-limit paths help isolate the frequency components relevant to the test method.

A ±500 V maximum input rating supports DC power-supply output checks, with 300.0 mVpp and 3,000 mVpp ripple/noise ranges. The manufacturer lists less than 90 ms fast-mode DC-voltage measurement, approximately 170 ms ripple/noise measurement, and configurable PASS/FAIL signals. Interface options include USB and GPIB; LAN requires the option.

Keisoku Giken currently lists a DP-100A differential probe among RM-104 package accessories, while legacy Denkei data refers to the DP-100. Confirm supplied accessories, required scanner channels and current calibration status with the quoted unit.

100 MHzTHRU filter upper frequency
±500 VMaximum DC input voltage
300 / 3,000 mVppRipple and noise ranges
PASS / FAILAutomation-ready judgments

Direct Numeric Ripple and Noise Readout

Compare power-supply ripple or noise levels as numeric values without relying solely on manual trace interpretation.

Five Ripple/Noise Components

Use the vendor-defined modes and filters to distinguish broadband ripple/noise, ripple, HF noise, switching ripple and AC ripple.

DC Voltage and Peak-to-Peak Ranges

Cover DC outputs up to ±500 V together with 300 mVpp and 3,000 mVpp ripple/noise ranges.

Selectable Measurement Bandwidth

THRU, low-pass, high-pass and 20 MHz limit paths help match the intended inspection procedure.

Automated PASS/FAIL Controls

Use set limits and photocoupler I/O signals to support repeatable production testing.

Network and Multi-Channel Expansion

Connect through USB/GPIB, add optional LAN, or integrate the separate SC-83 scanner for multiple test points.

Switching Power Supply Final Inspection

Quantify ripple and noise at the output of manufactured DC power supplies.

Power Supply Preventive Maintenance

Trend ripple levels at industrial power supplies and review changes that may indicate component aging.

DC/DC Converter Development

Compare peak-to-peak noise under different operating points or input/output conditions.

Automated Power Supply Testing

Use PASS/FAIL outputs and supported communications to record reproducible test results.

Filtering and Noise Troubleshooting

Isolate AC ripple and higher-frequency switching components using the selected measurement filter.

Infrastructure Equipment Service

Inspect DC power modules supporting plant, utility and industrial control equipment.

RM-104 Technical Specifications

The listed frequency paths are selectable measurement filters, not five separate simultaneously connected measuring channels. High-frequency setup and cabling can affect repeatability.

DC and Ripple/Noise Measurement

SpecificationRM-104
DC voltage ranges±6.0000 V; ±60.000 V; ±500.00 V
DC voltage resolution0.1 mV; 1 mV; 10 mV
Maximum applied input±500 V
DC voltage basic accuracy±0.025% of reading ±0.025% of full scale (manufacturer conditions)
DC voltage measurement time<90 ms FAST; <250 ms SLOW (published figures)
Ripple/noise ranges300.0 mVpp; 3,000 mVpp
Ripple/noise resolution0.1 mV; 1.0 mV
Ripple/noise accuracy±2% of reading ±1% of full scale (published conditions)
Ripple/noise measurement timeApprox. 170 ms (specified conditions)
THRU filter50 Hz–100 MHz
Low-pass filter50 Hz–2 kHz
High-pass filter2 kHz–100 MHz
20 MHz bandwidth limit50 Hz–20 MHz
Ripple separation ratio adjustment0–50%, selectable 0.5% increments

Interfaces, Environment and Accessories

SpecificationRM-104
Standard communicationUSB 2.0; GPIB / IEEE 488.1
Optional LAN interfaceYes; confirm option with quotation
Production controlPASS/FAIL output, trigger input, scanner/control signals
Multi-channel expansionOptional SC-83 scanner with 8 inputs; up to 16 inputs with two units
Input terminationDC input impedance approx. 1 MΩ; 50 Ω high-frequency path
Measurement cablingVendor lists DP-100A differential probe as current package accessory; confirm exact revision
AC mains power85–264 V AC; 50/60 Hz
Power consumption30 VA or less
Dimensions180 × 85 × 300 mm (W × H × D)
MassApprox. 1.8 kg
Operating environment0–40 °C; 20–85% RH, non-condensing