Home » Electronic Measuring Instruments » Bidirectional & Bipolar Power Sources » Bidirectional Power Supply » Keisoku Giken Ene-phant Series Bidirectional Regenerative DC Power Supply

Keisoku Giken Ene-phant Series Bidirectional Regenerative DC Power Supply

Ene-phant 50 kW Bidirectional Regenerative DC Power Systems

The Keisoku Giken Ene-phant NT-AD-50K-B family sources DC power and absorbs energy from the device under test, returning suitable absorbed power to the facility power system.

Three 50 kW model ratings cover up to 350 V and ±300 A (NT-AD-50KD-B), 750 V and ±200 A (NT-AD-50KH-B), and 1,500 V and ±100 A (NT-AD-50KO-B). This source/sink architecture supports high-capacity battery testing and regenerative power-conversion evaluation.

The manufacturer specifies power-regeneration / power-conversion efficiency of 90% at rated input/output conditions, with CC, CV and CP operation. Direction switching is automatic in CV mode and manual in CC/CP modes, according to the published mode specification.

50 kWRated power per base unit
350 / 750 / 1,500 VThree rated DC voltage classes
Up to 250 kWFive-unit parallel configurations
90%Manufacturer-stated rated-condition efficiency

A single unit can be configured within the published voltage/current/power operating envelope. Up to five identical models can be operated in parallel; series use is restricted to supported models and must follow the manufacturer’s instructions.

For North American projects, confirm grid-side supply voltage, protection functions, installation scope and local approval requirements before committing to a model or installation design.

Bidirectional Source/Sink Operation

Supply power to a DUT or absorb energy from it for reversible power-flow testing; regenerative mode can return energy to the connected grid.

Three Voltage-Class Models

Select 350 V / ±300 A, 750 V / ±200 A or 1,500 V / ±100 A nominal voltage/current classes, each rated 50 kW.

Scalable Power Capacity

Manufacturer lists up to five matching units in parallel for 250 kW; confirm the required master/slave wiring and equipment configuration.

CC, CV and CP Control

Current, voltage and power modes accommodate controlled test operating points; switching behavior varies by mode.

Regenerative Conversion Efficiency

Manufacturer specifies 90% at rated input/output conditions; actual energy recovery depends on operating point and facility conditions.

Remote Control and Protection

Published interfaces include LAN, RS-232C and digital/analog I/O, with voltage/current/power limits and emergency-stop functions.

EV Battery Pack Cycling

Source and absorb bidirectional current in suitable high-capacity rechargeable battery charge/discharge test systems.

DC-DC Converter Testing

Evaluate DC converter power-flow behavior and operating points under controlled source/sink conditions.

Vehicle On-Board Charger Development

Test applicable high-voltage DC-side source/sink scenarios as part of OBC validation.

Inverter DC-Link Evaluation

Provide a controlled DC source/sink environment for selected inverter and motor-drive DC-link tests.

Energy Storage System R&D

Characterize battery-connected power systems in engineering laboratories with energy recovery capability.

Regenerative Converter Validation

Evaluate power-electronics subsystems that return energy during braking, discharge or reverse power flow.

Ene-phant NT-AD-50K-B Technical Specifications

Instrument typeRegenerative bidirectional DC power supply / source-sink
Rated power per base unit50 kW
Operating modesCV / CC / CP
Manufacturer conversion/regeneration efficiency90% at rated input/output conditions
Minimum operating voltage0 V
Power setting range0 to ±50 kW
Voltage setting resolution0.1 V
CC response time≤10 ms (10%–90%)
CV response time≤50 ms (10%–90%)
CV source/sink switchingAutomatic
CC / CP source/sink switchingManual
Maximum parallel units5 identical-model units; up to 250 kW
Series connectionUp to two identical 350 V or 750 V units; factory option and no concurrent parallel operation. 1,500 V model cannot be series-connected.
Remote control / communicationLAN, RS-232C, digital I/O and analog control
Grid-side input (Japan specification)Three-phase 3-wire 400 V ±40 V, 50/60 Hz ±2 Hz; verify U.S. electrical compatibility with manufacturer
Grid protectionManufacturer-described grid monitoring and protection; local certification must be verified

NT-AD-50K-B Model Comparison

SpecificationNT-AD-50KD-BNT-AD-50KH-BNT-AD-50KO-B
Rated DC voltage350 V750 V1,500 V
Rated bidirectional current±300 A±200 A±100 A
Rated power50 kW50 kW50 kW
CV setting range0–350 V0–750 V0–1,500 V
Maximum 5-unit parallel current±1,500 A±1,000 A±500 A
Maximum 5-unit parallel power250 kW250 kW250 kW
Series operationUp to 2 (factory option)Up to 2 (factory option)Not supported

50 kW is the rated power limit: the maximum voltage and maximum current should not be assumed available simultaneously. “90%” is the published rated-condition efficiency, not an unconditional energy-saving guarantee. Source/sink transition behavior is mode-specific (CV automatic; CC and CP manual).

Regeneration, Facility Input and Ene-phant Product Scope

Product scope: This Denkei page covers Ene-phant NT-AD-50K-B bidirectional regenerative DC power supplies, not the manufacturer’s separately offered Ene-phant regenerative DC electronic-load or AC/DC electronic-load products. Use separate pages for those platforms.

Operating envelope: Confirm voltage, current, power and transient duty at each expected DUT operating point. At the rated 50 kW power ceiling, full voltage and maximum current are not available concurrently.

Series/parallel constraints: Up to five matching models in parallel are documented. The NT-AD-50KO-B (1,500 V) is not suitable for series connection, and supported series configurations require manufacturer-defined options and restrictions.

Installation review: Japanese specifications describe three-phase 400 V (±40 V), 50/60 Hz input. U.S. installation requires manufacturer confirmation of grid-voltage options, transformers if applicable, local grid interconnection / safety requirements and available service.

Related Denkei solution: Use DC Power & Bidirectional Testing Solutions for application navigation. A separate Keisoku Giken RPS-5000 page can compare the manufacturer’s newer regenerative combo supply.