Home » Electronic Measuring Instruments » Electronic Loads » Electronic Load » GW Instek PEL-3000A / PEL-3000AH Programmable DC Electronic Load

GW Instek PEL-3000A / PEL-3000AH Programmable DC Electronic Load

Programmable DC Electronic Loads for Power Supply and Battery Testing

The GW Instek PEL-3000A / PEL-3000AH Series provides high-performance programmable DC electronic loads for evaluating switching power supplies, DC/DC converters, batteries, and automotive power electronics under static and dynamic load conditions.

The series includes two voltage classes: PEL-3000A models rated up to 150 VDC and PEL-3000AH models rated up to 800 VDC. Both families offer 175 W, 350 W, and 1050 W single-channel load models, with compatible 2100 W booster units available for higher-power configurations.

150 V / 800 V Standard and high-voltage DC load families
16 A/µs Maximum PEL-3000A current slew rate
9,450 W Maximum supported multiunit load configuration
LAN Standard Remote control for automated testing

Seven programmable operating modes—Constant Current (CC), Constant Voltage (CV), Constant Resistance (CR), Constant Power (CP), CC+CV, CR+CV, and CP+CV—allow engineers to simulate a wide variety of DC load conditions. Dynamic switching from 0.0166 Hz to 20 kHz, programmable sequences, and GO/NO-GO testing support repeatable product verification.

The PEL-3000A family provides a maximum current slew rate of 16 A/µs for fast load transitions. The PEL-3000AH family supports high-voltage applications up to 800 V, with a maximum slew rate of 0.84 A/µs and front-panel voltage monitoring capability.

Standard USB, RS-232/RS-485, and LAN connectivity enable integration into automated test systems, while optional GPIB supports additional instrument-control environments. A 3.5-inch TFT display, configurable protection functions, and analog monitoring interfaces provide flexible local and remote operation.

For higher-power requirements, compatible PEL-3111A or PEL-3111AH units can be combined with matching booster modules. The maximum 9,450 W capacity refers to a supported multiunit configuration, not an individual electronic load.

150 V and 800 V Load Configurations

Choose PEL-3000A models for DC loads up to 150 V or PEL-3000AH models for high-voltage testing up to 800 V. Both families offer 175 W, 350 W, and 1050 W standalone units.

Seven Programmable Load Modes

Supports CC, CV, CR, CP, CC+CV, CR+CV, and CP+CV operating modes to evaluate power supplies, converters, and battery systems under different electrical conditions.

High-Speed Dynamic Load Simulation

Generates dynamic switching loads from 0.0166 Hz to 20 kHz. Maximum slew rates reach 16 A/µs on PEL-3000A and 0.84 A/µs on PEL-3000AH, depending on model and operating conditions.

Programmable Sequences and GO/NO-GO Testing

Supports normal and fast sequences, automated test programs, 100 setup memories, and GO/NO-GO evaluation for repeatable engineering and production testing.

Expandable High-Power Load Capacity

Combines compatible PEL-3111A or PEL-3111AH main units with matching 2100 W booster modules, supporting engineered multiunit load configurations up to 9450 W.

Standard LAN and Remote Control

Includes USB, RS-232/RS-485, and LAN interfaces for automated test integration. Optional GPIB, analog monitoring, remote sense, and configurable protection functions expand control capabilities.

Switching Power Supply Testing

Evaluate output regulation, load response, and performance of switching power supplies used in servers, industrial computers, and electronic equipment.

DC/DC Converter Validation

Apply constant and dynamic DC loads to verify converter performance, transient response, and output stability under changing operating conditions.

EV and Automotive Power Electronics

Use 800 V PEL-3000AH models to evaluate compatible high-voltage DC outputs from automotive chargers, converters, and related power electronics.

Battery Discharge Testing

Apply controlled current and power loads to characterize battery discharge behavior, voltage response, and performance within the instrument's rated operating limits.

Server and Telecom Power Supply Testing

Simulate changing load demand for server, data center, networking, and telecommunications power equipment during development and verification.

Automated Production and Reliability Testing

Integrate programmable load sequences, GO/NO-GO checks, and remote instrument control into production inspection and reliability evaluation systems.

Model Type Voltage Rating Maximum Current Rated Power
PEL-3021A DC Electronic Load 150 V 35 A 175 W
PEL-3041A DC Electronic Load 150 V 70 A 350 W
PEL-3111A DC Electronic Load 150 V 210 A 1050 W
PEL-3211A Booster for PEL-3111A 150 V 420 A 2100 W
PEL-3021AH High-Voltage DC Electronic Load 800 V 8.75 A 175 W
PEL-3041AH High-Voltage DC Electronic Load 800 V 17.5 A 350 W
PEL-3111AH High-Voltage DC Electronic Load 800 V 52.5 A 1050 W
PEL-3211AH Booster for PEL-3111AH 800 V 105 A 2100 W
Specification PEL-3000A PEL-3000AH
Rated Voltage Class 150 VDC 800 VDC
Standalone Load Power 175 W / 350 W / 1050 W 175 W / 350 W / 1050 W
Compatible Booster PEL-3211A, 2100 W PEL-3211AH, 2100 W
Maximum Multiunit Capacity 9450 W with supported configuration 9450 W with supported configuration
Maximum Current Slew Rate 16 A/µs 0.84 A/µs
Operating Modes CC, CV, CR, CP, CC+CV, CR+CV, CP+CV CC, CV, CR, CP, CC+CV, CR+CV, CP+CV
Dynamic Switching Frequency 0.0166 Hz to 20 kHz 0.0166 Hz to 20 kHz
Soft Start 1 to 200 ms, 1 ms resolution 1 to 200 ms, 1 ms resolution
Sequence Functions Normal and Fast Sequence Normal and Fast Sequence
Automated Test Functions GO/NO-GO, Program GO/NO-GO, Program
Protection Functions OCP, OVP, OPP, UVP OCP, OVP, OPP, UVP
Setup Memory 100 sets 100 sets
Display 3.5-inch TFT LCD 3.5-inch TFT LCD
Standard Interfaces USB, RS-232/RS-485, LAN USB, RS-232/RS-485, LAN
Optional Interface GPIB GPIB
External Control Analog control and monitoring Analog control and monitoring
Front-Panel Voltage Monitor Confirm model-specific connectors BNC voltage monitor

Model ratings represent maximum voltage, current, and power limits, which cannot necessarily be achieved simultaneously. The maximum 9450 W configuration requires a compatible PEL-3111A/AH main unit with four matching PEL-3211A/AH booster units. Boosters are not standalone electronic loads. Maximum slew rate and dynamic performance depend on the selected model and operating conditions. Confirm compatible accessories and final configuration before quotation.