Flexible semi-anechoic facilities for radiated emissions and immunity testing
The NPR-RIKEN Semi-Anechoic Chamber is a configurable shielded EMC environment for investigating electromagnetic emissions and equipment susceptibility during research, validation and compliance-oriented test development.
The manufacturer offers designs with a 3 m measurement distance, including an example 4.0 × 8.0 × 3.5 m chamber. The chamber may use a metallic ground-plane floor or absorber floor depending on the intended measurement method and site constraints.
Published reference configurations mention ANSI C63.4, CISPR 16-1-4 and IEC 61000-4-3, plus combined ferrite tile and RHFFP absorber systems. The cited 1–18 GHz interval is labeled “Site Attenuation” by the manufacturer; it should be treated as a listed high-frequency reference interval, not a dB attenuation or universal certified range.
Actual EMC compliance depends on chamber validation, antenna arrangements, equipment under test, site-attenuation and field-uniformity measurements, the current test-standard edition and test system integration. Specify these as project deliverables rather than assuming a reference layout guarantees compliance.