SANYO DENKI SANUPS E11B is a single-phase hybrid UPS that combines Economy and Double Conversion modes. Its automatic operating-mode selection aims to balance energy efficiency and dependable power quality for electronic controls, server equipment and other critical loads.

The E11B series has a wide input operating range, reducing avoidable transfers to battery when the incoming AC supply deviates from nominal. The manufacturer cites 55–150 V for some 100 V models at less than 40% load in Double Conversion mode. This broadest range must not be stated without its load qualification; other load levels have narrower ranges.

In the referenced 1 kVA E11B102A001AM model, the rated output is 1 kVA / 0.8 kW with a nominal 100/110/115/120 V output configuration. The nominal backup time is listed as three minutes at 0.8 power factor, with five minutes shown in parentheses at 0.7 power factor, based on new fully charged batteries at 25°C. Backup duration therefore depends on the selected model, load and battery condition.

The E11B can be installed in a range of environments. SANYO DENKI specifies -10 to +55°C for general versions; UL/CE-certified variants have a +40°C upper limit. Input/output plug options and applicable certification must be matched to the intended market, and the remote battery cold-start function is disabled by default.

Compatible SANUPS SOFTWARE, LAN interface cards and external battery arrangements are available depending on model. For a lithium-ion alternative with a longer manufacturer-stated service-life target, compare the SANUPS E11B-Li family; battery chemistry and rated backup time differ.

2 modes Economy and Double Conversion
1–3 kVA Sizes present in manufacturer lineup
55–150 V 100 V variant, Double Conversion, load under 40%
-10 to +55°C General versions; UL/CE limit is +40°C

Two-Mode Hybrid Operation

Automatically select Economy or Double Conversion to balance power quality and efficiency.

Wide AC Input Tolerance

Reduce unnecessary battery transfers when supply voltage is unstable; supported range varies by load.

Conditioned Inverter Output

Use Double Conversion to regulate output voltage for sensitive equipment.

Application-Specific Connections

Select appropriate rated voltages, plugs and receptacle options for the site.

Cold Start from Battery

Enable inverter operation without AC mains when the battery cold-start setting has been activated.

Monitoring and Shutdown Options

Integrate compatible SANUPS SOFTWARE and separately selected LAN/contact interfaces.

Industrial Automation Controls

Supply UPS backup for PLCs, control panels and sensitive equipment interfaces.

Communication Systems

Protect routers and communication hardware during temporary supply disturbances.

Servers and Edge Computing

Support a controlled shutdown of computers and local equipment cabinets.

Medical Equipment Infrastructure

Provide backup to eligible non-life-support electrical systems after qualified power design review.

Factory Monitoring and Data Logging

Keep monitoring electronics active while power events are detected and logged.

Power-Quality Improvement

Limit battery cycling and maintain conditioned output in facilities with unstable mains.

SANYO DENKI SANUPS E11B Hybrid UPS Specifications

Product familySANUPS E11B Hybrid UPS
UPS topologyTwo-mode hybrid
Operating modesEconomy and Double Conversion
Battery chemistryValve-regulated lead-acid (VRLA), model-dependent
Series rated output1, 1.5, 2 and 3 kVA shown in manufacturer lineup
Example modelE11B102A001AM
Example output capacity1 kVA / 0.8 kW
Example input / output voltage100 / 110 / 115 / 120 V AC
Rated output frequency50 / 60 Hz for referenced model
Nominal backup time, 1 kVA example3 min at PF 0.8; (5 min at PF 0.7), new fully charged battery, 25°C
Input voltage range, 100 V example55–150 V at load <40%; 68–144 V at load <70%; 80–144 V at load ≥70%; Double Conversion mode
Economy mode input rangeWithin ±8% of rated voltage in referenced model
Rated input frequency50 / 60 Hz
Input frequency range40–120 Hz in asynchronous Double Conversion operation; synchronization requirements differ
Output voltage regulationDouble Conversion: ±2%; Economy: -10% to +8% of rated voltage, referenced model
Input power factor≥0.95 in referenced model
Battery reference lifeApprox. 5 years; operating conditions affect replacement interval
Cold startBattery cold start available; disabled by default
General operating temperature-10 to +55°C
UL/CE certified operating temperatureUpper limit +40°C according to manufacturer series page
Installation formatsVertical / rack-mount variants, depending on order code
Interfaces / UPS managementCompatible software, Ethernet interface card and dry-contact accessories available separately
Regional certificationsVerify exact variant, labeling and standards for the destination market

Figures are manufacturer-published series information or explicitly identified model examples. Ratings, backup time, regulatory approvals, battery service life, options and availability vary with the exact order code, environment and load. Confirm the final configuration with Denkei Americas before ordering.